Alarm Technician Security Protocols Flashcards
7 cards from real CAT practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Alarm Technician Security Protocols flashcards as text
Which NFPA standard governs the installation of household fire warning equipment?
Answer: NFPA 72
NFPA 72, the National Fire Alarm and Signaling Code, covers installation, maintenance, and testing of fire warning systems including household equipment.
A technician discovers that a commercial alarm system uses an older 110-baud pulse dialer as its only communicator. The recommended upgrade path is to:
Answer: Add a dual-path IP/cellular communicator meeting current standards
Modern standards and many AHJs require dual-path communication; IP/cellular communicators provide redundancy and faster signal delivery.
When a technician performs a system handoff to the customer, which item is essential to document and provide?
Answer: User codes, zone descriptions, and operating instructions
The customer must receive user codes, zone information, and operating instructions to manage their system safely and effectively.
Which scenario describes a 'cross-zone' alarm requirement?
Answer: Two detectors in adjacent zones must both trip within a set time before an alarm is transmitted
Cross-zone logic requires two detectors to activate within a defined period, reducing false alarms while still ensuring genuine events are reported.
What is the purpose of an anti-masking feature in a passive infrared motion detector?
Answer: It detects attempts to cover or block the detector and triggers a tamper alarm
Anti-masking technology uses microwave or IR sensing to detect when the detector's lens is covered, which could defeat the sensor.
A customer's alarm activates but the central station never receives a signal. After checking the communicator, the technician finds it is sending signals but the panel's dialer delay is set to 45 seconds. Why is this significant?
Answer: The dialer delay allows time to cancel accidental alarms before transmission, but if the customer disarms within that window no signal is sent
The dialer delay is intentional to allow false alarm cancellation, but it means disarming within 45 seconds prevents any central station notification.
According to best practices, how often should a completed alarm system receive a full functional test?
Answer: Annually, or as required by local authority having jurisdiction (AHJ)
NFPA 72 and most jurisdictions require at least annual testing of alarm systems, though the AHJ may specify more frequent intervals.