โ† All CAT Flashcard Decks

Alarm Technician Security Protocols Flashcards

7 cards from real CAT practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Alarm Technician Security Protocols flashcards as text
  1. A technician notices an alarm panel is connected to the internet via the customer's unmanaged consumer router. The best recommendation is to:

    Answer: Suggest moving the panel to a dedicated VLAN or a separate secured network connection

    Placing alarm communicators on a dedicated VLAN isolates them from general network traffic and reduces exposure to cyber threats.

  2. Which document defines the levels of alarm system monitoring service quality and technician standards in the US?

    Answer: UL 2050

    UL 2050 is the standard for central station alarm monitoring services, covering operations, personnel, and response procedures.

  3. What is a 'duress code' in an alarm system?

    Answer: A secondary user code that signals the central station the user is being forced to disarm

    A duress code (often one digit off the normal code) arms or disarms normally but sends a silent duress signal to the central station.

  4. When testing motion detectors after installation, which environmental condition must the technician account for?

    Answer: Heat sources or HVAC drafts that could cause false alarms

    PIR motion detectors detect infrared heat differences; HVAC vents and heat sources can cause nuisance alarms if not considered.

  5. According to SIA False Alarm Reduction guidelines, what should a technician recommend if a customer reports more than 3 false alarms per year?

    Answer: Conduct a site survey to identify and correct the source of false activations

    A site survey identifies root causes of repeated false alarms, such as environmental interference, improper sensor placement, or user error.

  6. A technician is installing a glass break detector in a room with both plate glass and tempered glass windows. What consideration applies?

    Answer: The technician should test with the appropriate flex or shock stimulator for each glass type

    Different glass types (plate, laminated, tempered) produce different break frequencies, and the detector must be tested with the correct stimulator for each type present.

  7. What is the primary security concern with leaving a control panel in 'walk test' mode after completing an installation?

    Answer: It prevents the system from sending alarm signals to the central station

    Walk test mode typically prevents alarm transmissions or reduces them, leaving the property unmonitored if the mode is not exited.