โ† All CSC Flashcard Decks

Quality Control & Assurance Flashcards

7 cards from real CSC practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Quality Control & Assurance flashcards as text
  1. A cardiac electrophysiology lab tracks its rate of vascular access complications as a quality metric. This is most accurately classified as:

    Answer: An outcome measure

    Vascular access complication rates reflect what happens to patients as a result of care, making them outcome measures.

  2. Which of the following best describes the concept of 'high reliability organization' (HRO) as applied to a cardiac intensive care unit?

    Answer: An organization that operates in complex, high-risk environments yet consistently avoids catastrophic failures through specific cultural and operational practices

    HROs are characterized by preoccupation with failure, reluctance to simplify, sensitivity to operations, commitment to resilience, and deference to expertise.

  3. The 'spec limit' concept in Six Sigma applied to door-to-balloon time in STEMI refers to:

    Answer: The upper specification limit of 90 minutes defined by clinical guidelines as the performance boundary

    Specification limits define the acceptable performance boundaries; in STEMI care, the 90-minute upper spec limit is set by ACC/AHA guidelines.

  4. A cardiac surgery program wants to compare its observed-to-expected (O/E) mortality ratio using risk-adjusted data. An O/E ratio less than 1.0 indicates:

    Answer: The program's mortality is lower than expected, suggesting performance above the national benchmark

    An O/E ratio below 1.0 means fewer patients died than the risk model predicted, indicating better-than-expected performance.

  5. In echocardiography quality assurance, 'turnaround time' from image acquisition to finalized report is monitored as a:

    Answer: Process measure

    Turnaround time reflects the timeliness of the reporting process and is classified as a process measure in cardiac imaging QA.

  6. Which action is most appropriate when a control chart shows a data point outside the upper control limit (UCL) for contrast dose in a cardiac cath lab?

    Answer: Investigate for a special cause of variation and take corrective action

    A point outside the control limits signals a special (assignable) cause of variation that requires investigation and corrective action.

  7. Which of the following is the MOST effective strategy for sustaining quality improvements in a cardiac care program long-term?

    Answer: Embedding the improvement into standard operating procedures, policies, and ongoing monitoring systems

    Sustainability requires hardwiring changes into the system through standardized policies, protocols, and ongoing measurement rather than relying on individual effort.