โ† All CAR Flashcard Decks

Inspection & Quality Control Flashcards

7 cards from real CAR practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Inspection & Quality Control flashcards as text
  1. When inspecting a refrigerator for recycling, which component must be checked for CFC content before processing?

    Answer: Refrigerant in the sealed system

    Refrigerant trapped in the sealed system must be identified and recovered because CFCs are ozone-depleting substances regulated under the Clean Air Act.

  2. A quality control inspector finds a window air conditioner with a cracked compressor housing. What is the most critical immediate concern?

    Answer: Potential refrigerant leak into the environment

    A cracked compressor housing can release refrigerant, which is an ozone-depleting or greenhouse gas and must be contained before recycling.

  3. Which standard is most commonly referenced when inspecting used appliances for hazardous material content in a US recycling facility?

    Answer: EPA Section 608

    EPA Section 608 of the Clean Air Act governs the handling, recovery, and recycling of refrigerants in appliances.

  4. During incoming inspection, a technician notices a washing machine has a strong chemical odor. The correct first action is to:

    Answer: Tag and quarantine it for hazmat evaluation

    Unknown chemical odors indicate possible hazardous residue; the unit must be quarantined and evaluated before any further processing.

  5. What information should be recorded on a receiving log when an appliance arrives at a CAR-certified facility?

    Answer: Unit type, refrigerant type if applicable, and source

    CAR certification requires documentation of unit type, refrigerant information, and source to maintain chain-of-custody and regulatory compliance.

  6. An inspector identifies a chest freezer that uses R-600a (isobutane) as its refrigerant. What special handling precaution applies?

    Answer: Handle with flammability precautions due to R-600a's combustible nature

    R-600a is a flammable hydrocarbon refrigerant, requiring spark-free equipment and flammability precautions during recovery.

  7. When performing a visual quality control check on a dehumidifier, which finding would cause an immediate rejection from the standard recycling stream?

    Answer: Visible PCB-containing capacitors in damaged condition

    Damaged PCB-containing capacitors are a hazardous waste requiring special handling and cannot enter the standard recycling stream.