  1. Gamma radiation sterilization is most commonly applied to which category of medical products?

    Answer: Single-use plastic devices and pre-packaged sterile products

    Gamma radiation is widely used by manufacturers for terminal sterilization of single-use plastic devices and packaged sterile products because it penetrates packaging without heat damage.

  2. In the Spaulding Classification System, a flexible endoscope that contacts mucous membranes is designated as a:

    Answer: Semi-critical item requiring at minimum high-level disinfection

    Flexible endoscopes contact mucous membranes and are classified as semi-critical items, requiring at minimum high-level disinfection between patients.

  3. Which low-temperature sterilization technology is commonly used in hospitals for heat-sensitive devices such as certain flexible endoscopes and electronic components?

    Answer: Hydrogen peroxide gas plasma sterilization

    Hydrogen peroxide gas plasma sterilization operates at approximately 50°C, making it suitable for heat-sensitive devices such as certain scopes and electronic equipment.

  4. A biomedical technician finds that a biological indicator from a sterilization load has returned a positive result. What is the most appropriate immediate action?

    Answer: Recall all items from that load and report the failure to the infection control team

    A positive biological indicator signals sterilization failure; all items from the affected load must be recalled and quarantined, and the event reported to infection control for investigation.

  5. Which organization publishes ANSI/AAMI ST79, the comprehensive guideline for steam sterilization and sterility assurance in health care facilities?

    Answer: Association for the Advancement of Medical Instrumentation (AAMI)

    AAMI (Association for the Advancement of Medical Instrumentation) publishes ANSI/AAMI ST79, the primary U.S. guideline for steam sterilization practices in healthcare facilities.

  6. What minimum PPE combination is required when manually decontaminating soiled surgical instruments in a central sterile department?

    Answer: Utility gloves, fluid-resistant gown, surgical mask, and eye protection

    Manual decontamination requires utility gloves, a fluid-resistant gown, a mask, and eye protection to protect workers from bloodborne pathogen exposure and chemical splashes.

  7. The principle of event-related sterility asserts that a sterilized package:

    Answer: Remains sterile as long as packaging integrity is maintained, regardless of elapsed time

    Event-related sterility holds that a package remains sterile indefinitely as long as its integrity is preserved; sterility is compromised by events (damage, moisture, contamination), not time.