CABT Cheat Sheet 2026
The 30 highest-yield CABT facts, distilled from real exam questions. Print it, save it as a PDF, or study it here β free, no sign-up.
120 questions
120 min time limit
70% to pass
- The primary function of electrical isolation in patient monitoring equipment is to: β Prevent dangerous current from flowing through the patient to ground
- A ventilator's flow sensor reads consistently 15% higher than the reference standard during calibration. This is an example of: β Systematic bias (offset error)
- The term 'slew rate' in an operational amplifier refers to: β Maximum rate of change of output voltage
- Which risk management standard is specifically applicable to the design and manufacture of medical devices? β ISO 14971
- In the structural hierarchy of the human body, which level of organization is considered more complex than tissues? β Organs
- What is the term for the connective tissue that attaches muscle to bone? β Tendon
- Which layer of the heart wall is responsible for the contractile function of the heart? β Myocardium
- In Certified Associate in Biomedical Technology practice, what is the CORRECT sequence when performing a technical procedure? β Plan, prepare, execute, verify, and document
- During a nuclear medicine gamma camera quality control test, a 'uniformity flood' is performed to check: β Homogeneous sensitivity response across the detector face
- What is the primary function of a laminar flow hood in a clinical laboratory? β To provide a sterile work environment by directing HEPA-filtered air over the work surface
- When calibrating an invasive blood pressure transducer, zeroing the transducer at the level of the phlebostatic axis compensates for: β Hydrostatic pressure error due to fluid column height
- According to the Spaulding Classification System, surgical instruments that enter sterile tissue or the vascular system are classified as: β Critical items
- Which of the following best describes 'risk priority number' (RPN) used in Failure Mode and Effects Analysis (FMEA)? β The product of severity, occurrence, and detectability ratings for a failure mode
- Which biological indicator organism is the standard for testing the efficacy of steam sterilization? β Geobacillus stearothermophilus spores
- What is the role of the sinoatrial (SA) node in cardiac physiology? β It initiates the electrical impulse that sets the heart rate
- ISO 13485 is a quality management standard specifically designed for: β Organizations in the medical device supply chain
- During a 12-lead ECG procedure, which electrode placement is considered the reference point (Wilson's central terminal) for augmented unipolar limb leads? β Average of right arm, left arm, and left leg electrodes
- In Certified Associate in Biomedical Technology, what is the PRIMARY purpose of conducting an initial assessment? β To establish a baseline and identify needs for appropriate action
- What is the primary purpose of the 'alarm limit' feature on patient monitors? β To alert clinicians when a parameter exceeds safe boundaries
- In a biomedical pressure transducer using a strain gauge, what electrical parameter changes in response to physical deformation? β Resistance
- A Class I recall is initiated when a device has a reasonable probability of causing: β Serious adverse health consequences or death
- Which type of epithelium lines the urinary bladder and is capable of stretching? β Transitional epithelium (urothelium)
- Which of the following is the correct action when a medical device is found with a frayed power cord during a PM inspection? β Remove the device from service and replace the cord before returning it
- Which test instrument is used to measure the insulation resistance of medical electrical equipment to detect degraded insulation? β Megohmmeter (megger)
- When calibrating a pressure transducer to atmospheric pressure, the biomedical technician should confirm the displayed pressure reads: β 0 mmHg
- What is the most important factor in effective communication with patients regarding patient monitoring? β Using clear, understandable language and confirming understanding
- What temperature and pressure are maintained during a standard gravity displacement steam sterilization cycle? β 121Β°C (250Β°F) at 15 psi
- In ultrasound imaging, axial resolution is primarily determined by: β Transducer frequency and pulse length
- Which sterilization method is most appropriate for heat-sensitive flexible endoscopes? β Ethylene oxide (EtO) or hydrogen peroxide gas plasma
- Which ultrasound imaging mode displays the amplitude of returning echoes as vertical spikes plotted against depth? β A-mode