C7 C7 Audio Visual & Communication Systems 2 — Questions and Answers
Question 1: Which protocol is the industry standard for controlling lighting and AV equipment in modern California commercial installations?
- DMX-512 (Correct answer)
- RS-232
- BACnet
- Modbus
Correct answer: DMX-512
DMX-512 is the standard digital protocol used by C7 contractors for controlling dimmers, LED fixtures, and theatrical lighting in commercial AV installations.
Question 2: What is the purpose of a balun in an audio/video distribution system?
- To amplify signal strength
- To convert between balanced and unbalanced signal formats or impedances (Correct answer)
- To split one signal into multiple outputs
- To filter out high-frequency noise
Correct answer: To convert between balanced and unbalanced signal formats or impedances
A balun (balanced-unbalanced transformer) converts between balanced and unbalanced signal types, allowing coaxial-to-twisted-pair runs over structured cabling.
Question 3: Per California electrical code, low-voltage wiring for AV systems run in a plenum space must use cable rated as:
- CL2
- CMR (riser rated)
- CMP (plenum rated) (Correct answer)
- Any listed cable with conduit
Correct answer: CMP (plenum rated)
CMP-rated (Communications Plenum) cable is required in plenum air-handling spaces because it has low smoke and flame-spread characteristics per NEC Article 800.
Question 4: What is the recommended separation distance between low-voltage AV cables and 120V power conductors when run in parallel without conduit?
- At least 2 inches
- At least 6 inches (Correct answer)
- At least 12 inches
- No separation required
Correct answer: At least 6 inches
NEC guidelines and industry best practice recommend at least 6 inches of separation between power and low-voltage signal cables to minimize inductive interference.
Question 5: Which fiber optic connector type is most commonly used for HDMI-over-fiber AV extender systems in California commercial installations?
- SC
- ST
- LC (Correct answer)
- FC
Correct answer: LC
LC connectors are the dominant choice for modern AV-over-fiber systems due to their small form factor and compatibility with SFP transceivers.
Question 6: An AV system integrator under a C7 license installs a ceiling speaker system. Which document must be provided to the building owner at project completion?
- Manufacturer's warranty card only
- As-built drawings showing speaker locations and cable routing (Correct answer)
- Only the permit inspection card
- A signed NDA
Correct answer: As-built drawings showing speaker locations and cable routing
California contractors are required to provide as-built documentation so building owners and future technicians can maintain, service, or modify the installed system.
Which protocol is the industry standard for controlling lighting and AV equipment in modern California commercial installations?