Before servicing any high-voltage (HV) component on a hybrid/electric vehicle, what is the FIRST safety step?
-
A
Remove the 12V auxiliary battery
-
B
Disable the high-voltage system using the service disconnect plug or procedure specified by the OEM, verify voltage is zero with a Category III or IV meter, then use insulated HV gloves
-
C
Turn off the ignition and proceed immediately
-
D
Discharge HV capacitors by shorting the terminals with a screwdriver