Per ACI 318, what strength reduction factor φ applies to flexure in a tension-controlled reinforced concrete section?
Answer: 0.90
Tension-controlled sections are ductile and receive φ = 0.90.
A section is classified as tension-controlled under ACI 318 when the net tensile strain in the extreme tension steel is at least:
Answer: 0.005
Net tensile strain εt ≥ 0.005 defines a tension-controlled section.
What is the specified minimum yield strength of ASTM A992 structural steel wide-flange shapes?
Answer: 50 ksi
ASTM A992 steel has Fy = 50 ksi and is the standard grade for W-shapes.
What is the theoretical effective length factor K for a column fixed against rotation and translation at both ends?
Answer: 0.5
Fixed-fixed end conditions give a theoretical K of 0.5.
How does the Euler critical buckling load of a column change if its effective length is doubled?
Answer: It drops to one-quarter
Pcr = π²EI/(KL)², so doubling KL cuts Pcr to one-quarter.
Per ACI 318, the modulus of elasticity of normal-weight concrete is approximately:
Answer: 57,000√f'c psi
For normal-weight concrete, Ec ≈ 57,000√f'c in psi.
Per ACI 318, what is the minimum clear cover for cast-in-place concrete cast against and permanently exposed to earth?
Answer: 3 in.
Concrete cast directly against earth needs 3 in. of cover to protect the reinforcement.