ARRT Computed Tomography (CT) Certification Examination — Questions and Answers
Question 1: Which of the following best explains why ARRT periodically revises its CT examination content specifications?
- To match content used by competing certification bodies
- To satisfy JRCERT annual audit requirements
- To align the examination with evolving clinical practice identified through practice analysis (Correct answer)
- To increase examination difficulty and reduce pass rates
Correct answer: To align the examination with evolving clinical practice identified through practice analysis
ARRT updates content specifications based on practice analysis data to ensure examinations reflect what entry-level technologists actually need to know in current clinical settings.
Question 2: What is the mechanism of an anaphylactoid (allergic-like) reaction to iodinated contrast media?
- Cytotoxic T-cell destruction of endothelial cells
- Non-IgE-mediated direct mast cell and basophil activation independent of prior sensitization (Correct answer)
- Complement activation by iodine forming immune complexes
- IgE-mediated mast cell degranulation identical to classic allergy
Correct answer: Non-IgE-mediated direct mast cell and basophil activation independent of prior sensitization
Anaphylactoid reactions to contrast are non-IgE-mediated; contrast directly activates mast cells and basophils, releasing histamine and other mediators without requiring prior sensitization.
Question 3: Which of the following correctly defines 'effective dose' (E) in radiation protection?
- The absorbed dose to a single organ multiplied by the quality factor
- The dose measured at the surface of a standard phantom
- The weighted sum of equivalent doses to all irradiated tissues, reflecting overall stochastic risk (Correct answer)
- The total energy deposited in the patient during a CT scan
Correct answer: The weighted sum of equivalent doses to all irradiated tissues, reflecting overall stochastic risk
Effective dose uses tissue weighting factors to sum equivalent doses across organs, yielding a single value (in mSv) that represents whole-body stochastic risk.
Question 4: A technologist is scanning a patient with metal hip implants. To reduce dose while managing metal artifact, which approach is MOST appropriate?
- Skip the hip region entirely regardless of clinical indication
- Double the mAs in the hip region to overpower artifacts
- Switch to a lower kVp to increase contrast resolution
- Use metal artifact reduction (MAR) software at standard dose rather than routinely increasing mAs (Correct answer)
Correct answer: Use metal artifact reduction (MAR) software at standard dose rather than routinely increasing mAs
Metal artifact reduction software effectively manages implant artifacts at standard dose; routinely increasing mAs adds unnecessary patient dose without eliminating artifacts.
Question 5: What is the primary radiation hazard associated with CT compared to conventional radiography?
- Higher peak kilovoltage
- Use of radioactive isotopes as contrast agents
- Significantly greater patient dose due to multiple rotational acquisitions and extended scan volumes (Correct answer)
- Greater secondary radiation reaching personnel in adjacent rooms
Correct answer: Significantly greater patient dose due to multiple rotational acquisitions and extended scan volumes
CT delivers substantially higher patient doses than conventional radiography because it involves multiple rotational X-ray acquisitions covering large anatomical volumes.
Question 6: Which entity must sponsor a continuing education activity for it to count toward ARRT CT recertification?
- The technologist's employing hospital
- The American College of Radiology only
- An ARRT-approved CE sponsor (Correct answer)
- Any national radiology organization
Correct answer: An ARRT-approved CE sponsor
ARRT only accepts Category A CE credits from activities provided by ARRT-approved sponsors, ensuring quality and relevance.
Question 7: What is the role of the ARRT Board of Trustees in the accreditation and credentialing process?
- They govern ARRT policy, including eligibility requirements and ethical standards (Correct answer)
- They perform on-site inspections of clinical training sites
- They issue state radiologic technology licenses
- They directly score individual certification examinations
Correct answer: They govern ARRT policy, including eligibility requirements and ethical standards
The ARRT Board of Trustees is the governing body responsible for setting policy, eligibility criteria, and ethical standards for the organization.
Question 8: On axial CT of the chest, the right and left main bronchi are best distinguished because:
- The left main bronchus is shorter and more vertical than the right
- The right main bronchus is shorter and more vertical, making aspiration more likely (Correct answer)
- The left main bronchus has a larger caliber than the right
- The right main bronchus is longer and more horizontal than the left
Correct answer: The right main bronchus is shorter and more vertical, making aspiration more likely
The right main bronchus is shorter, wider, and more vertical, which is why aspirated foreign bodies most commonly lodge on the right side.
Question 9: What is homeostasis?
- A type of cell division
- A disease state
- The body's ability to maintain stable internal conditions (Correct answer)
- An organ system
Correct answer: The body's ability to maintain stable internal conditions
Homeostasis is the body's dynamic process of maintaining stable internal conditions (temperature, pH, blood sugar) despite external changes.
Question 10: On axial brain CT, the internal capsule is bounded medially by which structure?
- Caudate nucleus (Correct answer)
- Globus pallidus
- Putamen
- Thalamus
Correct answer: Caudate nucleus
The anterior limb of the internal capsule is bounded medially by the head of the caudate nucleus.
Question 11: A patient receiving oxygen via nasal cannula at 2 L/min needs a portable chest X-ray. The technologist should:
- Discontinue oxygen as it interferes with imaging
- Switch the patient to a face mask before imaging
- Remove the oxygen cannula during the exposure
- Leave the oxygen in place and proceed with the exam (Correct answer)
Correct answer: Leave the oxygen in place and proceed with the exam
Supplemental oxygen should not be interrupted; nasal cannulas do not significantly affect image quality and the patient's oxygenation status must be maintained.
Question 12: On axial CT of the abdomen, the superior mesenteric artery (SMA) is typically located:
- Within the hepatoduodenal ligament
- Posterior to the splenic vein
- Directly anterior to the abdominal aorta, surrounded by fat (Correct answer)
- Lateral to the inferior vena cava
Correct answer: Directly anterior to the abdominal aorta, surrounded by fat
The SMA arises from the anterior aorta and is typically seen as a vessel surrounded by a halo of mesenteric fat on axial CT.
Question 13: Which of the following is an example of a breach of patient confidentiality?
- Documenting contrast administration in the patient's chart
- Confirming a patient's identity before beginning a procedure
- Sharing patient imaging results with the ordering physician
- Discussing a patient's case with a family member without patient consent (Correct answer)
Correct answer: Discussing a patient's case with a family member without patient consent
Under HIPAA, patient health information may not be shared with family members without the patient's explicit consent, except in specific circumstances.
Question 14: When creating coronal MPR images from a helical chest CT, image quality is best when the original acquisition used:
- Thin slices (≤1 mm) reconstructed at overlapping intervals (0.5–0.7 mm) (Correct answer)
- High pitch with standard soft tissue kernel only
- Large FOV and minimal overlap
- Thick slices (5–10 mm) reconstructed at 5 mm intervals
Correct answer: Thin slices (≤1 mm) reconstructed at overlapping intervals (0.5–0.7 mm)
Thin, overlapping reconstructions produce near-isotropic voxels that allow high-quality coronal and sagittal reformations without visible stair-step artifacts.
Question 15: What is the first priority in any emergency situation?
- Save equipment
- Contact the media
- Write a report
- Ensure the safety of all personnel (Correct answer)
Correct answer: Ensure the safety of all personnel
In any emergency, the first priority is always the safety and well-being of all personnel. Equipment and materials can be replaced; lives cannot.
Question 16: Which CT post-processing technique displays only voxels above a selected threshold, making it useful for 3D visualization of bones and vascular structures?
- Maximum intensity projection (MIP) (Correct answer)
- Volume rendering (VR)
- Surface shaded display (SSD)
- Multiplanar reformation (MPR)
Correct answer: Maximum intensity projection (MIP)
Maximum intensity projection (MIP) selects and displays the highest attenuation voxel along each ray through the dataset, ideal for visualizing contrast-enhanced vessels or calcifications.
Question 17: On axial brain CT, the sylvian fissure (lateral sulcus) separates which lobes?
- Parietal lobe from occipital lobe
- Frontal and parietal lobes from the temporal lobe (Correct answer)
- Frontal lobe from occipital lobe
- Frontal lobe from the parietal lobe only
Correct answer: Frontal and parietal lobes from the temporal lobe
The sylvian (lateral) fissure separates the frontal and parietal lobes superiorly from the temporal lobe inferiorly.
Question 18: Which reconstruction kernel (filter) should be chosen to minimize noise when imaging soft tissue structures in the abdomen?
- Ultra-high resolution kernel
- Smooth or standard soft tissue kernel (Correct answer)
- Bone or edge-enhancing kernel
- Lung kernel
Correct answer: Smooth or standard soft tissue kernel
Soft tissue kernels apply low-pass filtering that smooths the image and reduces noise, which is appropriate for abdominal soft tissue evaluation.
Question 19: What are the principles of mission command?
- Rank, authority, obedience
- Technology, firepower, logistics
- Speed, power, aggression
- Competence, mutual trust, shared understanding, commander's intent (Correct answer)
Correct answer: Competence, mutual trust, shared understanding, commander's intent
Mission command empowers subordinates through trust, shared understanding of the commander's intent, and disciplined initiative.
Question 20: Which of the following is a non-financial benefit of ARRT CT certification that directly impacts a technologist's daily work?
- Increased confidence and clinical decision-making ability in CT protocols (Correct answer)
- Automatic scheduling priority for day shifts
- Exemption from hospital-wide mandatory training
- Reduced number of CT scans assigned per shift
Correct answer: Increased confidence and clinical decision-making ability in CT protocols
Preparing for and passing the CT exam deepens protocol knowledge, which enhances the technologist's confidence and quality of clinical decisions.
Question 21: A CT technologist holds both Radiography (R) and CT credentials. How many CE credits are required biennially?
- 24 total, shared across all credentials (Correct answer)
- 12 per credential for a total of 24
- 48 total (24 per credential)
- 24 R-specific + 12 CT-specific = 36
Correct answer: 24 total, shared across all credentials
ARRT allows CE credits to be shared across all held credentials, so 24 credits per 2-year cycle satisfies requirements for multiple credentials.
Question 22: A hospital's Imaging Director wants to ensure staff are competent in CT protocols. Which credential most directly validates CT-specific competency?
- OSHA safety training certificate
- ARRT CT post-primary certification (Correct answer)
- ACR accreditation badge
- Basic Life Support (BLS) certification
Correct answer: ARRT CT post-primary certification
ARRT CT post-primary certification specifically validates a technologist's advanced knowledge and skills in computed tomography.
Question 23: CT calcium scoring of the coronary arteries uses which post-processing method to quantify calcification?
- MIP projection over the cardiac cycle
- Subtraction of non-contrast from contrast images
- Agatston scoring based on lesion area and peak Hounsfield unit density (Correct answer)
- Volume rendering with opacity mapping
Correct answer: Agatston scoring based on lesion area and peak Hounsfield unit density
Agatston scoring multiplies the area of each calcified lesion by a density factor based on peak HU (1–4 scale), then sums all lesions to yield the total calcium score.
Question 24: On CT spine, which finding is most consistent with a herniated nucleus pulposus at L4-L5 causing left leg radiculopathy?
- Central disc bulge at L3-L4
- Right paracentral disc protrusion compressing the L4 nerve root in the lateral recess
- Left paracentral disc extrusion compressing the left L5 nerve root (Correct answer)
- Left foraminal stenosis at L3-L4
Correct answer: Left paracentral disc extrusion compressing the left L5 nerve root
A left paracentral extrusion at L4-L5 compresses the traversing L5 nerve root in the lateral recess, causing ipsilateral radiculopathy.
Question 25: A ring or band artifact centered on the image is most likely caused by a malfunction of which CT component?
- Gantry motor
- X-ray tube
- Collimator
- A single detector element (Correct answer)
Correct answer: A single detector element
Ring artifacts result from a miscalibrated or malfunctioning detector element producing a circular artifact at a fixed radius from the isocenter.
Question 26: For a CT-guided biopsy protocol, which parameter is typically reduced to minimize patient dose during the procedure?
- Tube current (mA) (Correct answer)
- Gantry rotation speed
- Tube voltage (kVp)
- Slice thickness
Correct answer: Tube current (mA)
Fluoroscopic CT guidance uses low-mA (fluoroCT) settings to reduce cumulative dose while maintaining adequate image quality for needle visualization.
Question 27: What type of artifact appears as bright or dark streaks radiating from high-density objects like metal implants in CT images?
- Ring artifact
- Partial volume artifact
- Beam hardening artifact (Correct answer)
- Motion artifact
Correct answer: Beam hardening artifact
Beam hardening artifacts appear as streaks or dark bands radiating from dense metallic objects because lower-energy photons are preferentially absorbed.
Question 28: For a CT scan of the spine performed to evaluate for disk herniation, which reconstruction kernel is preferred?
- Lung (high-frequency) kernel
- Bone (high-frequency) kernel
- Ultra-high-resolution kernel
- Standard soft tissue kernel (Correct answer)
Correct answer: Standard soft tissue kernel
A standard or intermediate soft tissue kernel is preferred for disk and neural structure evaluation, reducing noise while preserving relevant detail.
Question 29: To troubleshoot a CT image showing significant noise (grainy appearance), the technologist should first consider adjusting which parameter?
- Reducing matrix size
- Increasing pitch
- Decreasing kVp
- Increasing mAs (Correct answer)
Correct answer: Increasing mAs
Increasing mAs raises the number of X-ray photons, directly reducing quantum noise and improving signal-to-noise ratio.
Question 30: What is the ALARA principle in radiation safety?
- As Low As Reasonably Achievable — minimize radiation exposure (Correct answer)
- Always Lock And Restrict Access
- All Labs And Rooms Assessed
- Automated Limiting Adjustment for Radiation Applications
Correct answer: As Low As Reasonably Achievable — minimize radiation exposure
ALARA means keeping radiation doses as low as reasonably achievable while still obtaining diagnostic-quality images, balancing benefit against risk.
Question 31: The 'cupping artifact' in CT, where the center of a uniform object appears less dense than its periphery, is a manifestation of which phenomenon?
- Aliasing
- Partial volume averaging
- Quantum noise
- Beam hardening (Correct answer)
Correct answer: Beam hardening
Cupping artifact is a form of beam hardening where the edges of the object appear brighter because the beam hardens less traveling a shorter path length.
Question 32: A 'ring artifact' in CT is most commonly caused by:
- Too high a pitch value
- Incorrect window/level settings
- Patient motion during scanning
- A malfunctioning or miscalibrated detector element (Correct answer)
Correct answer: A malfunctioning or miscalibrated detector element
Ring artifacts form concentric circles centered on the scanner's isocenter when one or more detector channels give consistently incorrect readings.
Question 33: Which of the following best describes the purpose of the ARRT pre-application ethics review?
- To assess continuing education compliance only
- To evaluate past violations before a candidate invests in examination preparation (Correct answer)
- To waive clinical competency requirements for candidates with clean records
- To replace the formal application process
Correct answer: To evaluate past violations before a candidate invests in examination preparation
The pre-application ethics review allows candidates with potential concerns to learn their eligibility status before paying fees and preparing for the exam.
Question 34: On a CT system, what does the term 'isocenter' refer to?
- The precise center of gantry rotation where the X-ray beam and detector array intersect (Correct answer)
- The center of the X-ray beam at the detector plane
- The center of the patient table surface
- The midpoint of the scan field of view display
Correct answer: The precise center of gantry rotation where the X-ray beam and detector array intersect
The isocenter is the exact point at the center of gantry rotation where the X-ray beam is focused, and proper patient centering at this point optimizes image quality and dose.
Question 35: Which of the following correctly describes 'isotropic voxels' in CT?
- Voxels that contain only one tissue type
- Voxels with equal x, y, and z dimensions (Correct answer)
- Voxels calibrated to HU = 0
- Voxels with a z-dimension larger than x and y
Correct answer: Voxels with equal x, y, and z dimensions
Isotropic voxels have equal dimensions in all three planes, enabling high-quality multiplanar reformations without resolution loss.
Question 36: Which ACR-recommended CT quality control test should be performed if visual image artifacts are noted during clinical scanning?
- Reduce the scan FOV and repeat without QC evaluation
- Immediately repeat the patient scan at higher mAs
- Switch to a different reconstruction kernel and continue scanning
- Perform artifact analysis using an appropriate phantom and document findings before continuing clinical use (Correct answer)
Correct answer: Perform artifact analysis using an appropriate phantom and document findings before continuing clinical use
When clinical artifacts are observed, ACR guidelines require phantom-based artifact analysis and documentation before continuing patient scanning to ensure diagnostic image quality.
Question 37: What prerequisite must a radiologic technologist fulfill before sitting for the ARRT CT certification examination?
- Holding a current ARRT primary certification and meeting CT clinical experience requirements (Correct answer)
- Passing the American Board of Radiology oral examination
- Obtaining approval from the state radiologic technology board
- Completing a two-year CT fellowship program
Correct answer: Holding a current ARRT primary certification and meeting CT clinical experience requirements
Candidates must hold a current ARRT primary certification and document the required number of CT clinical procedures before applying for the CT post-primary exam.
Question 38: 3D volume rendering of CT data allows the display of internal structures through which technique?
- Selecting only the highest attenuation voxel per projection ray
- Assigning opacity values to voxels based on their Hounsfield units (Correct answer)
- Subtracting bone from the dataset
- Applying a smooth kernel to the raw data
Correct answer: Assigning opacity values to voxels based on their Hounsfield units
Volume rendering assigns transfer functions that map each HU value to a color and opacity, allowing semi-transparent visualization of multiple tissue types simultaneously.
Question 39: In CT, the filtered back projection (FBP) reconstruction algorithm applies a mathematical filter primarily to:
- Remove quantum noise before reconstruction
- Align misregistered projection data
- Segment soft tissue from bone
- Correct for star artifacts inherent in simple back projection (Correct answer)
Correct answer: Correct for star artifacts inherent in simple back projection
FBP applies a ramp or other convolution filter to projection data before back-projecting to eliminate the blurring ('star artifact') produced by simple back projection.
Question 40: Which of the following is the correct order of the surgical hand-scrub process?
- Remove jewelry, scrub hands and forearms with antiseptic, rinse from fingers to elbows, dry, don gloves (Correct answer)
- Rinse, apply antiseptic, scrub hands, don gloves while wet
- Wash with soap, apply sterile gloves, perform exam
- Don gloves, scrub hands, rinse, dry
Correct answer: Remove jewelry, scrub hands and forearms with antiseptic, rinse from fingers to elbows, dry, don gloves
Proper surgical scrub progresses from fingers to elbows, rinsing in the same direction to move microbes away from the hands rather than toward them.
Question 41: Minimum intensity projection (MinIP) post-processing is particularly useful for displaying which anatomical structures?
- Contrast-enhanced blood vessels
- Dense bone and calcifications
- Solid abdominal organs
- Air-filled airways and lung parenchyma (Correct answer)
Correct answer: Air-filled airways and lung parenchyma
MinIP projects the lowest attenuation voxel along each ray, making it ideal for displaying air-containing structures like the tracheobronchial tree or emphysematous lung.
Question 42: What does the term 'detector efficiency' refer to in CT scanner performance?
- The number of detector rows in the system
- The FOV coverage per rotation
- The speed at which the gantry rotates
- The ability of detectors to capture and convert X-ray photons into usable signal (Correct answer)
Correct answer: The ability of detectors to capture and convert X-ray photons into usable signal
Detector efficiency describes how effectively CT detectors absorb incident X-ray photons and convert them into electrical signal, directly affecting image quality and dose.
Question 43: Which patient condition is an absolute contraindication to intravascular iodinated contrast media administration?
- Age over 70 years
- Serum creatinine of 1.2 mg/dL
- Previous severe anaphylactic reaction to iodinated contrast without premedication (Correct answer)
- History of mild contrast allergy treated with antihistamines
Correct answer: Previous severe anaphylactic reaction to iodinated contrast without premedication
A prior severe anaphylactic contrast reaction is a contraindication unless the patient is premedicated and the benefit outweighs the risk; the radiologist must be involved.
Question 44: For a CT abdomen/pelvis with IV contrast, what is the typical scan delay after contrast injection to capture the nephrographic phase of the kidneys?
- 3–5 minutes
- 25–35 seconds
- 80–120 seconds (Correct answer)
- 10–15 seconds
Correct answer: 80–120 seconds
The nephrographic phase occurs approximately 80–120 seconds post-injection, when the renal cortex and medulla enhance uniformly, optimizing detection of renal masses.
Question 45: A horizontal band of decreased attenuation passing through the posterior fossa on a head CT is a classic example of which artifact?
- Beam hardening between the petrous bones (Correct answer)
- Ring artifact
- Partial volume artifact
- Motion artifact from cardiac pulsation
Correct answer: Beam hardening between the petrous bones
The dense petrous temporal bones cause preferential absorption of lower-energy photons, producing a dark band across the posterior fossa known as a beam hardening artifact.
Question 46: When negotiating a salary increase, a CT technologist cites their ARRT CT certification. Which argument is most compelling to the employer?
- The certification cost the technologist money to obtain
- Certified technologists reduce department liability by demonstrating validated competency (Correct answer)
- The credential was easy to earn and required minimal study
- The technologist now qualifies to perform radiologist duties
Correct answer: Certified technologists reduce department liability by demonstrating validated competency
Employers value that certified technologists have met a national standard, which reduces risk of errors, supports accreditation, and reflects positively on department quality.
Question 47: CT of the abdomen shows a 'target sign' (layered bowel wall with alternating attenuation) in the small bowel. This is most consistent with:
- Intussusception or inflammatory bowel disease with submucosal edema (Correct answer)
- Malignant bowel obstruction
- Bowel infarction
- Bowel perforation
Correct answer: Intussusception or inflammatory bowel disease with submucosal edema
The CT target sign reflects bowel wall stratification due to submucosal edema or fat, seen in intussusception, Crohn's disease, or ischemia.
Question 48: When performing a venipuncture for contrast administration, the needle bevel should be oriented:
- Facing down toward the vein wall
- Parallel to the skin surface, bevel sideways
- At a 90-degree angle to the skin
- Facing up (bevel up) (Correct answer)
Correct answer: Facing up (bevel up)
The bevel-up orientation allows the needle to enter the vein smoothly and reduces the risk of piercing the posterior vein wall.
Question 49: In CT, the term 'pitch' for single-slice CT is calculated as:
- Table feed per rotation / slice thickness (Correct answer)
- Table speed / gantry rotation time
- kVp / mAs
- Detector width / field of view
Correct answer: Table feed per rotation / slice thickness
Pitch = table feed per 360° rotation divided by the nominal slice thickness; a pitch >1 means gaps exist between consecutive slices.
Question 50: On a coronal CT reconstruction, the right hemidiaphragm is typically higher than the left because:
- The right crus of the diaphragm is thicker than the left
- The right lung is larger and displaces the diaphragm inferiorly
- The liver occupies the right upper quadrant and elevates the right hemidiaphragm (Correct answer)
- The spleen is positioned more inferiorly than the liver
Correct answer: The liver occupies the right upper quadrant and elevates the right hemidiaphragm
The mass of the liver beneath the right hemidiaphragm elevates it approximately half a rib space higher than the left.
Question 51: Which reconstruction kernel (filter) should be selected to best visualize lung parenchyma and fine pulmonary detail?
- High-resolution (sharp/edge-enhancing) kernel (Correct answer)
- Liver kernel
- Brain kernel
- Soft tissue (smoothing) kernel
Correct answer: High-resolution (sharp/edge-enhancing) kernel
A high-resolution or edge-enhancing kernel accentuates fine structural detail needed for lung parenchyma evaluation, at the cost of increased noise.
Question 52: On axial CT of the head at the level of the fourth ventricle, which structure is immediately posterior to the fourth ventricle?
- Medulla oblongata
- Cerebellum (vermis) (Correct answer)
- Pons
- Choroid plexus
Correct answer: Cerebellum (vermis)
The cerebellar vermis forms the posterior wall of the fourth ventricle on axial CT images.
Question 53: What is the window level and window width on CT images?
- Patient positioning parameters
- Physical measurements of the CT scanner
- Scan speed controls
- Settings that control the brightness and contrast of displayed images (Correct answer)
Correct answer: Settings that control the brightness and contrast of displayed images
Window level sets the center brightness (what HU appears as middle gray) and window width controls contrast range (how many HUs span from black to white).
Question 54: CT perfusion imaging requires specialized post-processing to generate which type of parametric maps?
- Standardized uptake value (SUV) maps
- Hounsfield unit histograms
- Cerebral blood flow, cerebral blood volume, and mean transit time maps (Correct answer)
- Bone mineral density scores
Correct answer: Cerebral blood flow, cerebral blood volume, and mean transit time maps
CT perfusion post-processing applies deconvolution or maximum slope models to time-attenuation curves to produce quantitative maps of CBF, CBV, and MTT.
Question 55: The windmill artifact in multislice CT helical acquisitions is MOST pronounced when:
- High kVp is used with thin collimation
- High pitch values are combined with thick slice reconstruction (Correct answer)
- Low mAs is used with a smooth kernel
- Small FOV is selected with fine matrix
Correct answer: High pitch values are combined with thick slice reconstruction
Windmill artifact stems from undersampling in the z-direction; it is most visible with high pitch (sparse data) and thick reconstructions that exaggerate interpolation errors.
Question 56: The inverse square law states that radiation intensity is related to distance by which relationship?
- Intensity decreases linearly with distance
- Intensity is directly proportional to distance
- Intensity is inversely proportional to the cube of the distance
- Intensity is inversely proportional to the square of the distance (Correct answer)
Correct answer: Intensity is inversely proportional to the square of the distance
The inverse square law: I ∝ 1/d², meaning doubling the distance from the source reduces intensity to one-quarter of its original value.
Question 57: Which type of CT detector material is most commonly used in modern multi-detector CT (MDCT) systems due to its high conversion efficiency and fast decay time?
- Sodium iodide (NaI) crystal detectors
- Gadolinium oxysulfide (GOS) solid-state scintillators (Correct answer)
- Bismuth germanate (BGO) crystals
- Xenon gas ionization chambers
Correct answer: Gadolinium oxysulfide (GOS) solid-state scintillators
Modern MDCT scanners predominantly use solid-state scintillator detectors such as gadolinium oxysulfide because of their high X-ray absorption efficiency and rapid afterglow decay.
Question 58: What documentation does an ARRT candidate typically need to submit to verify clinical competency in CT?
- Employer payroll records
- Competency verification signed by a supervising radiologist or qualified technologist (Correct answer)
- A letter from the state radiology board
- ACR accreditation certificate of the facility
Correct answer: Competency verification signed by a supervising radiologist or qualified technologist
Clinical competency must be verified by a supervising qualified professional who can attest that the candidate performed required procedures.
Question 59: Which of the following is the primary reason for using a low-osmolar, non-ionic iodinated contrast agent for intravenous CT contrast?
- It significantly reduces the risk of adverse reactions compared to ionic agents (Correct answer)
- It is less expensive than ionic contrast
- It requires a lower injection rate
- It provides higher iodine concentration per mL
Correct answer: It significantly reduces the risk of adverse reactions compared to ionic agents
Non-ionic, low-osmolar contrast agents have a much lower rate of adverse reactions (including severe reactions) compared to older high-osmolar ionic agents.
Question 60: What is homeostasis?
- An organ system
- A disease state
- A type of cell division
- The body's ability to maintain stable internal conditions (Correct answer)
Correct answer: The body's ability to maintain stable internal conditions
Homeostasis is the body's dynamic process of maintaining stable internal conditions (temperature, pH, blood sugar) despite external changes.
Question 61: What does a noise index (NI) setting in automatic tube current modulation (ATCM) control?
- The target image noise level that drives mA adjustments (Correct answer)
- The maximum allowed kVp during the scan
- The number of reconstruction iterations applied
- The amount of bowtie filter attenuation
Correct answer: The target image noise level that drives mA adjustments
The noise index defines the target standard deviation of image noise; ATCM raises or lowers mA to achieve this noise target based on patient attenuation.
Question 62: When performing a CT colonography, the technologist selects a 0.625 mm detector row width versus 5 mm. This change PRIMARILY improves:
- Temporal resolution for cardiac gating
- Patient dose efficiency
- Longitudinal (z-axis) spatial resolution enabling multiplanar reformats (Correct answer)
- Contrast resolution for soft tissue differentiation
Correct answer: Longitudinal (z-axis) spatial resolution enabling multiplanar reformats
Thinner detector rows provide finer z-axis sampling, enabling isotropic voxels and high-quality multiplanar reformats for polyp detection.
Question 63: How does ARRT CT certification affect a technologist’s earning potential?
- It may result in a pay cut, depending on the region
- It provides a one-time bonus but no long-term salary benefits
- Certified technologists typically earn higher salaries compared to non-certified ones (Correct answer)
- It does not affect salary in any way
Correct answer: Certified technologists typically earn higher salaries compared to non-certified ones
ARRT CT certification signifies a higher level of specialized training and expertise, which is often reflected in compensation. Employers recognize the value of certified professionals, leading to certified technologists typically commanding higher salaries and better benefits compared to their non-certified counterparts.
Question 64: Which window setting is most appropriate for evaluating pulmonary nodules in the lung parenchyma?
- Window width ~400 HU, window level ~40 HU
- Window width ~1500 HU, window level ~-600 HU (Correct answer)
- Window width ~200 HU, window level ~80 HU
- Window width ~3000 HU, window level ~300 HU
Correct answer: Window width ~1500 HU, window level ~-600 HU
Lung windows use a wide width (~1500 HU) and negative level (~-600 HU) to display the full range of lung attenuation from air to soft tissue.
Question 65: What is the most effective way to prevent healthcare-associated infections?
- Proper hand hygiene (Correct answer)
- Cleaning the floor
- Wearing gloves at all times
- Taking antibiotics
Correct answer: Proper hand hygiene
Hand hygiene (washing with soap and water or using alcohol-based hand rub) is the single most effective measure for preventing the spread of infections in healthcare settings.
Question 66: A patient has a Foley catheter in place. When transferring this patient, the urinary drainage bag should be positioned:
- Below the level of the bladder to prevent backflow (Correct answer)
- Clamped during all transfers to avoid spillage
- Above the level of the bladder to maintain drainage
- Disconnected temporarily during the move
Correct answer: Below the level of the bladder to prevent backflow
The drainage bag must remain below bladder level at all times to use gravity for urine drainage and prevent backflow that could cause infection.
Question 67: On CT urography, a urothelial carcinoma of the ureter would most likely appear as:
- Smooth fusiform dilation of the ureter
- Intraluminal filling defect with upstream hydronephrosis (Correct answer)
- Ureteral wall calcification
- Periureteral fat stranding only
Correct answer: Intraluminal filling defect with upstream hydronephrosis
Urothelial carcinoma typically presents as an intraluminal filling defect causing partial or complete obstruction with upstream hydronephrosis.
Question 68: If the ARRT discovers that a candidate provided false information on their CT application, the consequence may include:
- A warning letter with no other action
- Permanent revocation of eligibility and any existing ARRT credentials (Correct answer)
- Mandatory retaking of the primary examination
- A 30-day suspension of testing privileges
Correct answer: Permanent revocation of eligibility and any existing ARRT credentials
Providing false information is an ethics violation that can result in permanent loss of eligibility and revocation of all ARRT credentials.
Question 69: Which of the following is the correct documentation entry after administering IV contrast?
- Contrast given — no issues noted
- Contrast given per radiologist order
- Patient tolerated procedure well
- Type of contrast, lot number, dose, route, rate, patient response, and technologist's signature (Correct answer)
Correct answer: Type of contrast, lot number, dose, route, rate, patient response, and technologist's signature
Complete contrast documentation must include the agent name, lot number, dose, route, rate of administration, patient response, and the administering technologist's identification.
Question 70: Which phenomenon explains why CT numbers for bone may appear elevated at the center of a thick bony structure compared to peripheral bone?
- Ring artifact
- Partial volume effect
- Beam hardening cupping artifact (Correct answer)
- Undersampling artifact
Correct answer: Beam hardening cupping artifact
Beam hardening causes preferential absorption of lower-energy photons; more hardening occurs centrally, leading to erroneously high CT numbers at bone edges and low values centrally (cupping).
Question 71: A technologist working in a trauma center wants to advance to a CT lead position. Which prerequisite is most commonly required by employers?
- Five years of emergency department experience only
- ARRT CT post-primary certification (Correct answer)
- A master's degree in radiologic science
- Completion of a vendor-specific scanner training course
Correct answer: ARRT CT post-primary certification
ARRT CT certification is the most universally recognized and commonly required credential for CT lead or supervisory positions.
Question 72: On CT of the head, lenticular (biconvex) hyperdensity is identified adjacent to the temporal bone. What is the most likely cause?
- Hypertensive hemorrhage
- Middle meningeal artery rupture causing epidural hematoma (Correct answer)
- Berry aneurysm rupture
- Bridging vein rupture causing subdural hematoma
Correct answer: Middle meningeal artery rupture causing epidural hematoma
Epidural hematomas result from middle meningeal artery injury and form a biconvex hyperdense collection limited by dural attachments at sutures.
Question 73: Increasing the x-ray tube voltage (kVp) in CT primarily results in:
- Lower mean photon energy and higher subject contrast
- Unchanged image quality but increased scan time
- Higher image noise and lower contrast
- Higher mean photon energy and reduced photoelectric interactions (Correct answer)
Correct answer: Higher mean photon energy and reduced photoelectric interactions
Higher kVp produces a higher mean photon energy beam with greater penetrating power; Compton scatter dominates over photoelectric effect, reducing subject contrast.
Question 74: When evaluating a CT image for streak artifacts emanating from a hip prosthesis, the BEST corrective technique is:
- Widening the reconstruction FOV
- Decreasing the mAs by 50%
- Increasing the kVp to 140
- Metal artifact reduction (MAR) reconstruction algorithm (Correct answer)
Correct answer: Metal artifact reduction (MAR) reconstruction algorithm
Metal artifact reduction algorithms use iterative or sinogram-based techniques to model and subtract metal-induced streaks from the image.
Question 75: The Hounsfield unit (HU) value of pure water is:
- +100
- 0 (Correct answer)
- +1000
- -1000
Correct answer: 0
By definition, pure water is assigned an HU value of 0 on the Hounsfield scale used in CT imaging.
Question 76: What is the window level and window width on CT images?
- Physical measurements of the CT scanner
- Scan speed controls
- Settings that control the brightness and contrast of displayed images (Correct answer)
- Patient positioning parameters
Correct answer: Settings that control the brightness and contrast of displayed images
Window level sets the center brightness (what HU appears as middle gray) and window width controls contrast range (how many HUs span from black to white).
Question 77: A patient states, 'I am Jehovah's Witness and refuse any blood transfusion.' The radiologic technologist should:
- Contact the patient's family to override the decision
- Proceed with the procedure and allow physicians to decide later
- Document the statement and notify the supervising clinician immediately (Correct answer)
- Disregard the statement as the patient may not understand their condition
Correct answer: Document the statement and notify the supervising clinician immediately
A competent adult patient has the right to refuse treatment; the technologist must document this and notify the care team to ensure informed refusal is properly handled.
Question 78: What physiologic mechanism underlies contrast-induced nephropathy (CIN)?
- Renal medullary ischemia and direct tubular cell toxicity from contrast (Correct answer)
- Obstructive uropathy from contrast precipitation in the collecting ducts
- Immune-mediated glomerulonephritis triggered by iodine
- Systemic vasodilation leading to prerenal azotemia
Correct answer: Renal medullary ischemia and direct tubular cell toxicity from contrast
CIN results from renal medullary vasoconstriction causing ischemia combined with direct cytotoxic effects of contrast on tubular epithelial cells.
Question 79: The windmill artifact seen in helical CT is most commonly associated with which acquisition parameter?
- Small reconstruction FOV
- High pitch values (Correct answer)
- Large detector collimation
- Low kVp
Correct answer: High pitch values
Windmill artifacts appear as alternating dark and bright streaks rotating around structures and are caused by the under-sampling that occurs at high pitch values.
Question 80: Which of the following best describes the purpose of ARRT's Standards of Ethics in the accreditation context?
- They outline equipment quality standards
- They define conduct requirements candidates must meet to obtain and maintain credentials (Correct answer)
- They establish imaging protocols
- They set radiation dose limits
Correct answer: They define conduct requirements candidates must meet to obtain and maintain credentials
The ARRT Standards of Ethics outline the professional conduct requirements that candidates and credential holders must satisfy.
Question 81: A CT technologist completes a 3-credit online module from an ARRT-approved sponsor. How should this be recorded?
- Only if the module includes a hands-on component
- As 3 Category A CE credits (Correct answer)
- As Category B self-study credit
- It counts only if completed before the renewal year begins
Correct answer: As 3 Category A CE credits
Online modules from ARRT-approved sponsors qualify as Category A CE credits and count toward the 24-credit renewal requirement.
Question 82: Which eGFR threshold does the ACR use to define increased risk for contrast-induced acute kidney injury when administering IV iodinated contrast?
- eGFR < 30 mL/min/1.73m² (Correct answer)
- eGFR < 45 mL/min/1.73m²
- eGFR < 90 mL/min/1.73m²
- eGFR < 60 mL/min/1.73m²
Correct answer: eGFR < 30 mL/min/1.73m²
The ACR Manual on Contrast Media identifies eGFR < 30 mL/min/1.73m² as the threshold for significantly increased risk of contrast-induced acute kidney injury.
Question 83: Multiplanar reformation (MPR) in CT refers to:
- Generating 3D surface models from volumetric data
- Reconstructing axial images into coronal, sagittal, or oblique planes (Correct answer)
- Applying color to CT images based on Hounsfield units
- Subtracting pre-contrast from post-contrast images
Correct answer: Reconstructing axial images into coronal, sagittal, or oblique planes
MPR uses the volumetric CT dataset to create reformatted images in any anatomical plane without additional radiation exposure to the patient.
Question 84: What is the primary purpose of the bow-tie filter in a CT scanner?
- Calibrate the detector array
- Remove scatter radiation from the detector
- Compensate for the cylindrical shape of patients to reduce peripheral dose (Correct answer)
- Increase tube current
Correct answer: Compensate for the cylindrical shape of patients to reduce peripheral dose
The bow-tie (wedge) filter shapes the beam so less radiation hits the thinner periphery of the patient, reducing dose and preventing detector saturation.
Question 85: Under the ARRT ethics requirement, which of the following past offenses is MOST likely to result in denial of CT certification eligibility?
- A civil lawsuit unrelated to healthcare
- Felony conviction related to the practice of radiologic technology (Correct answer)
- Unpaid parking tickets
- Minor traffic violation
Correct answer: Felony conviction related to the practice of radiologic technology
Felony convictions, especially those related to healthcare practice, are subject to ARRT ethics review and can result in denial.
Question 86: Quantum (photon) noise in CT images is most visible under which conditions?
- Fast pitch and narrow FOV
- High mAs and thin slices
- High kVp and wide window
- Low mAs or large patient size (Correct answer)
Correct answer: Low mAs or large patient size
Quantum noise increases when fewer photons reach the detectors, which occurs with low mAs settings or when X-rays are attenuated by a large patient.
Question 87: Which organization is primarily responsible for accrediting radiologic technology programs in the United States?
- ACR
- ACR-AAPM
- JRCERT (Correct answer)
- ARRT
Correct answer: JRCERT
The Joint Review Committee on Education in Radiologic Technology (JRCERT) is the primary accrediting body for radiologic technology programs.
Question 88: An ARRT credential holder moves to a state that requires separate state licensure. Which of the following is correct?
- JRCERT issues the state license upon request
- The technologist must retake the ARRT exam for state purposes
- State licensure is separate from ARRT certification and must be obtained independently (Correct answer)
- ARRT certification automatically fulfills state licensure requirements in all states
Correct answer: State licensure is separate from ARRT certification and must be obtained independently
ARRT certification and state licensure are distinct; technologists must comply with individual state requirements separately.
Question 89: At the level of the aortic arch on axial CT, which vessel arises first (most rightward/anterior) from the arch?
- Left common carotid artery
- Brachiocephalic (innominate) artery (Correct answer)
- Right subclavian artery
- Left subclavian artery
Correct answer: Brachiocephalic (innominate) artery
The brachiocephalic artery is the first and most rightward branch of the aortic arch, followed by the left common carotid and left subclavian.
Question 90: How does ARRT CT certification impact patient care?
- It guarantees faster patient turnaround times in CT imaging
- It reduces the cost of CT procedures for patients
- It improves patient care by ensuring that technologists are properly trained in CT safety and imaging protocols (Correct answer)
- It has no significant impact on patient care
Correct answer: It improves patient care by ensuring that technologists are properly trained in CT safety and imaging protocols
ARRT CT certification directly impacts patient care by guaranteeing that technologists have met rigorous standards for education, clinical competency, and ethical conduct. This ensures they are proficient in CT safety, proper imaging protocols, and patient interaction, leading to accurate diagnoses and safer procedures for patients.
Question 91: Which professional organization co-sponsors ARRT's Standards of Ethics alongside the Society of Radiologic Technologists?
- Joint Commission on Allied Health Personnel in Ophthalmology
- American Medical Association
- American Society of Radiologic Technologists (ASRT) (Correct answer)
- American College of Radiology
Correct answer: American Society of Radiologic Technologists (ASRT)
ARRT developed its Standards of Ethics in collaboration with the American Society of Radiologic Technologists (ASRT), the primary professional association for RT professionals.
Question 92: Which of the following best describes a 'Category A' CE credit in the ARRT system?
- Structured educational activity provided by an ARRT-approved sponsor (Correct answer)
- Clinical hours logged during overtime shifts
- Any learning activity self-reported by the technologist
- Peer-reviewed article reading logged in a journal
Correct answer: Structured educational activity provided by an ARRT-approved sponsor
Category A credits are earned through formal, structured educational activities provided by sponsors recognized and approved by ARRT.
Question 93: A 'blooming artifact' in CT most commonly results from:
- Incorrect HU calibration of the scanner
- Patient motion during acquisition
- Undersampling of high-frequency data
- High-density metallic objects causing overestimation of structure size (Correct answer)
Correct answer: High-density metallic objects causing overestimation of structure size
Blooming occurs when high-attenuation objects like metals or calcifications appear larger than their true size due to beam hardening and partial volume effects.
Question 94: Which window setting is most appropriate for evaluating acute intracranial hemorrhage on a non-contrast head CT?
- Soft tissue window (WW 400, WL 50)
- Bone window (WW 2000, WL 300)
- Brain window (WW 80, WL 35) (Correct answer)
- Lung window (WW 1500, WL -500)
Correct answer: Brain window (WW 80, WL 35)
The brain window (narrow width ~80 HU, level ~35 HU) provides optimal contrast between hyperdense blood and surrounding brain tissue.
Question 95: What is the largest organ in the human body?
- Brain
- Liver
- Skin (Correct answer)
- Heart
Correct answer: Skin
The skin is the largest organ, covering approximately 20 square feet in adults and weighing about 8 pounds. It serves as the primary barrier against the environment.
Question 96: Which factor does NOT directly influence the CTDI_vol value displayed on the CT console?
- Reconstruction kernel (filter) (Correct answer)
- kVp
- Tube current (mAs)
- Pitch
Correct answer: Reconstruction kernel (filter)
Reconstruction kernel is a post-processing parameter applied after data acquisition and does not change the radiation output; CTDI_vol reflects acquisition parameters only.
Question 97: A radiologic technologist holds R.T.(R)(CT) credentials. What do the letters in parentheses each represent?
- (R) = residency completed; (CT) = computed tomography board
- (R) = primary ARRT registration in Radiography; (CT) = post-primary CT certification (Correct answer)
- (R) = state registration; (CT) = federal CT permit
- (R) = Radiology degree; (CT) = computed tomography license
Correct answer: (R) = primary ARRT registration in Radiography; (CT) = post-primary CT certification
R.T.(R) denotes primary ARRT registration in Radiography, and (CT) denotes the additional post-primary CT certification earned.
Question 98: A technologist holds ARRT primary certification in Radiography and a post-primary in CT. How many total CE credits are required per cycle?
- 24 total, with at least 6 specific to CT
- 48 total — 24 for each credential separately
- 36 total — 24 for primary plus 12 for post-primary
- 24 total, shared across both credentials (Correct answer)
Correct answer: 24 total, shared across both credentials
ARRT allows the same 24 Category A CE credits to satisfy renewal requirements for both the primary and post-primary certifications simultaneously.
Question 99: Which technique is most commonly used to reduce metal artifact in CT imaging of patients with hip prostheses?
- Metal artifact reduction (MAR) software (Correct answer)
- Increasing slice thickness
- Decreasing kVp
- Using a smaller FOV
Correct answer: Metal artifact reduction (MAR) software
Metal artifact reduction (MAR) algorithms replace corrupted projection data near metal with interpolated data, significantly reducing streaking artifacts.
Question 100: What is the purpose of contrast media in CT scans?
- To enhance the visibility of specific structures and pathology (Correct answer)
- To speed up the scan
- To make the patient comfortable
- To reduce radiation dose
Correct answer: To enhance the visibility of specific structures and pathology
Contrast media (dye) enhances the visibility of blood vessels, organs, and abnormalities by changing how X-rays interact with specific tissues.
Question 101: The Hounsfield unit (HU) value of pure water is defined as:
- 0 HU (Correct answer)
- -1000 HU
- +500 HU
- +1000 HU
Correct answer: 0 HU
The CT number scale defines water as 0 HU and air as −1000 HU, with other tissues placed relative to these references.
Question 102: On axial CT at the level of L4-L5, which structure is found anterior to the vertebral body?
- Celiac axis
- Abdominal aortic bifurcation (Correct answer)
- Inferior mesenteric artery origin
- Superior mesenteric artery origin
Correct answer: Abdominal aortic bifurcation
The abdominal aorta bifurcates into the common iliac arteries at approximately the L4 vertebral level.
Question 103: Which of the following scenarios would make a technologist INELIGIBLE to apply for ARRT CT certification?
- Working in a facility that performs fewer than 50 CT scans per month
- Holding an ARRT credential that is currently suspended (Correct answer)
- Having graduated from a JRCERT-accredited program more than 3 years ago
- Holding both R and RT credentials simultaneously
Correct answer: Holding an ARRT credential that is currently suspended
A suspended credential is not considered active and unrestricted, which is a prerequisite for CT post-primary eligibility.
Question 104: Which of the following activities can count toward the continuing education credits for ARRT CT certification?
- Attending an industry conference
- All of the above (Correct answer)
- Completing a patient care workshop
- Publishing a research article in a professional journal
Correct answer: All of the above
ARRT accepts a wide range of activities for continuing education (CE) credits, provided they are relevant to the radiologic sciences. This includes attending industry conferences, participating in patient care workshops, and even publishing research articles in professional journals. The goal is to encourage diverse learning that enhances professional practice.
Question 105: Iodinated contrast media produces vascular enhancement in CT primarily because iodine:
- Increases the paramagnetic properties of blood
- Has a high atomic number that strongly attenuates X-rays (Correct answer)
- Reduces blood viscosity, increasing flow speed
- Emits positrons that scatter X-rays
Correct answer: Has a high atomic number that strongly attenuates X-rays
Iodine (atomic number 53) has a high atomic number that dramatically increases X-ray attenuation in blood vessels and tissues, creating contrast enhancement on CT.
Question 106: How many total attempts does ARRT allow a candidate to take the CT certification examination?
- Unlimited attempts
- 2 attempts
- 5 attempts
- 3 attempts (Correct answer)
Correct answer: 3 attempts
ARRT limits candidates to 3 total attempts to pass each post-primary examination, including CT.
Question 107: Under ARRT's ethics requirements, a technologist who is convicted of a felony must do which of the following?
- Self-report the conviction to ARRT (Correct answer)
- Request a voluntary suspension of registration
- Notify their state licensing board only
- Immediately surrender their certificate
Correct answer: Self-report the conviction to ARRT
ARRT's Standards of Ethics require technologists to self-report criminal convictions, including felonies, to the ARRT within 30 days.
Question 108: ARRT's recertification policy allows CE credits earned through which type of structured journal activity?
- Informal article reading without assessment
- Department-based journal clubs without an approved sponsor
- ARRT-approved self-assessment modules or journal-based CE with post-tests (Correct answer)
- Any peer-reviewed radiology journal subscription
Correct answer: ARRT-approved self-assessment modules or journal-based CE with post-tests
Journal-based CE activities qualify only when they include a post-test and are offered through an ARRT-approved sponsor, not casual reading alone.
Question 109: Which body administers the ARRT CT certification examination at testing centers?
- ARRT staff at ARRT headquarters
- Prometric (Correct answer)
- ACR regional offices
- JRCERT-affiliated schools
Correct answer: Prometric
ARRT partners with Prometric to deliver its certification examinations at testing centers nationwide.
Question 110: Which ARRT primary pathway requires holding an unrestricted radiography certification before applying for CT?
- Nuclear Medicine (N)
- Radiography (R) (Correct answer)
- Sonography (S)
- Radiation Therapy (T)
Correct answer: Radiography (R)
The primary CT pathway most commonly used requires holding an active, unrestricted ARRT Radiography (R) credential.
Question 111: Which section of the ARRT application requires disclosure of prior criminal history and ethics violations?
- Structured education section
- Reference section
- Ethics section (Correct answer)
- Clinical competency section
Correct answer: Ethics section
The ethics section of the ARRT application requires applicants to disclose criminal history, professional disciplinary actions, and other relevant ethical matters.
Question 112: Which structure separates the anterior and middle cranial fossae on axial CT?
- Clinoid processes only
- Petrous ridge of the temporal bone
- Crista galli of the ethmoid bone
- Lesser wing of the sphenoid bone (Correct answer)
Correct answer: Lesser wing of the sphenoid bone
The lesser wing of the sphenoid bone forms the posterior boundary of the anterior cranial fossa, separating it from the middle cranial fossa.
Question 113: Which statement BEST describes the relationship between CT noise and mAs?
- Noise is proportional to 1/√mAs (Correct answer)
- Noise is inversely proportional to mAs
- Noise is unaffected by mAs changes
- Noise is directly proportional to mAs
Correct answer: Noise is proportional to 1/√mAs
CT noise follows Poisson statistics; doubling mAs quadruples photons but only reduces noise by a factor of √2, making noise proportional to 1/√mAs.
Question 114: What is the effect of decreasing detector collimation (thinner slices) on image noise, assuming all other factors remain constant?
- Noise increases (Correct answer)
- Noise decreases
- Noise is unaffected
- Noise is eliminated
Correct answer: Noise increases
Thinner collimation means fewer photons contribute to each voxel, increasing statistical noise in the image.
Question 115: Which CT quality control phantom is most commonly used to evaluate CT number accuracy, noise, uniformity, and spatial resolution?
- AAPM CT performance phantom (Correct answer)
- MOSFET dosimetry phantom
- Leeds TOR phantom
- Alderson Rando phantom
Correct answer: AAPM CT performance phantom
The AAPM CT performance phantom contains inserts for testing multiple image quality parameters including HU accuracy, noise, and spatial resolution.
Question 116: Which pitch factor would result in the longest scan time for a given scan range?
- 1.0
- 1.5
- 0.5 (Correct answer)
- 2.0
Correct answer: 0.5
A lower pitch means the table moves more slowly relative to rotation speed, resulting in more overlap and a longer scan time.
Question 117: What does the term 'half-scan reconstruction' refer to in CT?
- Reconstructing only half the detector channels
- Using 180° + fan angle of data instead of a full 360° to reduce motion artifact (Correct answer)
- Reducing matrix size by half to speed processing
- Acquiring data with only half normal mAs
Correct answer: Using 180° + fan angle of data instead of a full 360° to reduce motion artifact
Half-scan reconstruction uses approximately 180° + fan beam angle of data, which can reduce cardiac or other motion artifacts by shortening effective scan time.
Question 118: A CT image shows ring artifacts. The MOST likely cause is:
- A malfunctioning or miscalibrated detector element (Correct answer)
- Too low an mAs setting
- Incorrect kVp selection
- Patient motion during scanning
Correct answer: A malfunctioning or miscalibrated detector element
Ring artifacts appear as circular bands centered on the isocenter and are caused by a single detector element producing consistently incorrect readings.
Question 119: Which scan parameter adjustment would best reduce streak artifact from dental fillings on a head/neck CT?
- Decrease tube voltage
- Decrease rotation time
- Increase tube current (mA)
- Use gantry tilt to avoid the plane of the fillings (Correct answer)
Correct answer: Use gantry tilt to avoid the plane of the fillings
Tilting the gantry angles the scan plane away from dense dental hardware, reducing the metal streak artifact through structures of interest.
Question 120: What is the first step in the ARRT CT certification process?
- Complete the required clinical competencies
- Obtain a recommendation letter from an employer
- Submit an online application through the ARRT portal (Correct answer)
- Schedule the CT certification exam
Correct answer: Submit an online application through the ARRT portal
The initial step in the ARRT CT certification process, after meeting all prerequisites, is to formally apply. This is done by submitting an online application through the official ARRT website portal. This application initiates the eligibility review and allows candidates to proceed with scheduling their exam.
Question 121: A candidate fails the ARRT CT examination. What is the minimum waiting period before their first retake?
- 1 year
- 6 months
- 3 months (Correct answer)
- 2 weeks
Correct answer: 3 months
ARRT requires a 3-month waiting period between examination attempts to allow candidates time for remediation.
Question 122: What is the main clinical use of dual-energy CT (DECT)?
- Eliminating the need for contrast agents entirely
- Material decomposition to differentiate tissue composition (e.g., iodine vs. calcium) (Correct answer)
- Increasing patient dose efficiency
- Reducing scan time by half
Correct answer: Material decomposition to differentiate tissue composition (e.g., iodine vs. calcium)
DECT acquires data at two different kVp levels; the difference in attenuation at each energy allows material decomposition to characterize tissue composition.
Question 123: How often must ARRT-certified technologists complete continuing education to maintain their credentials?
- Every 2 years (Correct answer)
- Every 3 years
- Every 5 years
- Every year
Correct answer: Every 2 years
ARRT requires 24 continuing education credits every 2 years to maintain certification.
Question 124: Respiratory motion artifacts on chest CT can best be minimized by:
- Using breath-hold technique during acquisition (Correct answer)
- Increasing kVp
- Widening the display window
- Increasing slice thickness
Correct answer: Using breath-hold technique during acquisition
Instructing the patient to suspend respiration during CT acquisition eliminates breathing motion, preventing blurring and step artifacts in the chest.
Question 125: A CT technologist completes 30 Category A credits in one renewal cycle. How many, if any, credits can be carried over to the next cycle?
- 6 credits can be carried over
- 0 credits — no carryover is allowed (Correct answer)
- All excess credits carry over automatically
- 12 credits can be carried over
Correct answer: 0 credits — no carryover is allowed
ARRT does not allow Category A CE credits to be carried over from one renewal cycle to the next.
Question 126: Which of the following best describes the CT appearance of the caudate lobe of the liver?
- A small segment located between the IVC and the fissure for the ligamentum venosum (Correct answer)
- Located posterior to the inferior vena cava and anterior to the portal vein
- Located between the gallbladder fossa and the fissure for the ligamentum teres
- The largest segment of the left hepatic lobe
Correct answer: A small segment located between the IVC and the fissure for the ligamentum venosum
The caudate lobe (segment I) lies between the IVC posteriorly and the fissure for the ligamentum venosum anteriorly.
Question 127: A patient is on hemodialysis and requires a contrast-enhanced CT. Which statement regarding iodinated contrast in dialysis patients is correct?
- Contrast can be given; iodinated agents are removed by dialysis and residual renal function is already negligible (Correct answer)
- Emergent dialysis must be performed within 1 hour of contrast to prevent harm
- Only half the standard contrast dose may be given regardless of clinical indication
- Contrast is absolutely contraindicated in dialysis patients
Correct answer: Contrast can be given; iodinated agents are removed by dialysis and residual renal function is already negligible
Dialysis-dependent patients have no significant residual renal function to protect; contrast can be given when clinically indicated, as dialysis will remove the agent.
Question 128: What is the correct order for donning PPE?
- Gown, mask, eye protection, gloves (Correct answer)
- Mask, gloves, gown, eye protection
- Gloves, gown, mask, eye protection
- Any order is acceptable
Correct answer: Gown, mask, eye protection, gloves
The correct donning sequence is gown first, then mask/respirator, eye protection/face shield, and gloves last. This prevents contamination during application.
Question 129: The ARRT Standards of Ethics is incorporated into the CT certification process primarily to:
- Confirm candidates' insurance coverage
- Assess candidates' academic GPA
- Verify candidates' financial standing
- Ensure candidates demonstrate professional integrity and moral character (Correct answer)
Correct answer: Ensure candidates demonstrate professional integrity and moral character
The Standards of Ethics screening ensures that only individuals with demonstrated professional integrity are certified.
Question 130: Which of the following describes the location of the zona incerta on axial CT brain images?
- A thin band of gray matter between the lenticular fasciculus and the thalamic fasciculus in the subthalamus (Correct answer)
- A sulcus separating the caudate from the putamen
- A white matter tract connecting the thalamus to the frontal lobe
- Gray matter located in the posterior limb of the internal capsule
Correct answer: A thin band of gray matter between the lenticular fasciculus and the thalamic fasciculus in the subthalamus
The zona incerta is a subthalamic gray matter band situated between the lenticular and thalamic fasciculi.
Question 131: In CT, contrast-to-noise ratio (CNR) is BEST described as:
- The difference in HU between two structures divided by image noise (Correct answer)
- The ratio of signal to detector dark current
- The number of line pairs per centimeter resolved
- The ability to detect objects of varying sizes
Correct answer: The difference in HU between two structures divided by image noise
CNR = (HU_structure − HU_background) ÷ noise standard deviation, quantifying how well a structure stands out against background noise.
Question 132: The pitch value in helical CT is defined as:
- Gantry rotation speed divided by table speed
- Slice thickness divided by detector row width
- Table travel per rotation divided by total beam collimation width (Correct answer)
- kVp divided by mA
Correct answer: Table travel per rotation divided by total beam collimation width
Pitch = table distance traveled per 360° rotation ÷ total collimated beam width, and values >1 indicate gaps in data coverage.
Question 133: To meet ARRT’s ethics requirements, which of the following is necessary?
- Take a separate ethics exam during the certification process
- Submit a personal statement of professional ethics
- Agree to follow the ARRT Standards of Ethics and report any potential violations (Correct answer)
- Pass a background check and provide character references
Correct answer: Agree to follow the ARRT Standards of Ethics and report any potential violations
The ARRT places a strong emphasis on ethical conduct within the radiologic technology profession. To meet their ethics requirements, candidates must formally agree to adhere to the ARRT Standards of Ethics, which outline professional responsibilities and conduct. This commitment includes reporting any potential violations, upholding the integrity of the profession.
Question 134: Which oral contrast agent is most commonly used in CT of the abdomen and pelvis to opacify the bowel?
- Manganese chloride solution
- Air alone as a negative contrast agent
- Barium sulfate suspension or dilute water-soluble iodinated contrast (Correct answer)
- Gadolinium-based oral agent
Correct answer: Barium sulfate suspension or dilute water-soluble iodinated contrast
Barium sulfate or dilute iodinated contrast (e.g., dilute Gastrografin) are the standard oral agents used to opacify the GI tract in abdominal/pelvic CT.
Question 135: CT colonoscopy (virtual colonoscopy) relies on which post-processing technique to create a simulated fly-through view of the colon lumen?
- Minimum intensity projection
- Subtraction imaging
- Volume rendering with endoluminal navigation (Correct answer)
- Maximum intensity projection
Correct answer: Volume rendering with endoluminal navigation
Volume rendering with endoluminal navigation uses the air-distended colon as a flight path, generating a simulated colonoscopic perspective of the mucosal surface.
Question 136: Which of the following is the correct action if a detector ring artifact is identified during a quality control check of the CT scanner?
- Decrease the FOV
- Continue scanning and note in the patient report
- Recalibrate the detector and notify the medical physicist (Correct answer)
- Increase mAs to compensate
Correct answer: Recalibrate the detector and notify the medical physicist
A ring artifact indicates a detector calibration issue that must be corrected by recalibration or service; the medical physicist should be notified per QC protocols.
Question 137: On a CT KUB (kidneys, ureters, bladder), which stone type appears LEAST dense (lowest Hounsfield units)?
- Cystine
- Calcium oxalate monohydrate
- Uric acid (Correct answer)
- Struvite
Correct answer: Uric acid
Uric acid stones are the least dense urinary calculi on CT (100–400 HU), compared to calcium-based stones which exceed 800 HU.
Question 138: Which daily CT quality control test verifies that CT numbers (Hounsfield Units) remain accurate and consistent?
- Slice thickness verification
- Noise index measurement
- CT number accuracy/linearity test (Correct answer)
- High-contrast spatial resolution test
Correct answer: CT number accuracy/linearity test
The CT number accuracy/linearity test confirms that scanned materials produce the expected HU values, ensuring diagnostic consistency.
Question 139: ARRT certification in CT is best described as which type of credential?
- Post-primary specialty certification (Correct answer)
- Academic degree credential
- State-issued license
- Entry-level primary certification
Correct answer: Post-primary specialty certification
CT certification is a post-primary specialty credential, meaning it is layered on top of a primary ARRT certification in a related discipline.
Question 140: Which CT feature differentiates an acute from a chronic subdural hematoma?
- Crescent shape
- Hypodense (low attenuation) appearance of the collection (Correct answer)
- Location over the convexity
- Mass effect on the brain
Correct answer: Hypodense (low attenuation) appearance of the collection
Chronic subdural hematomas become hypodense (isodense to CSF) over weeks as hemoglobin degrades, unlike acute hyperdense collections.
Question 141: The 'noise' measured in a CT image is quantified as:
- The mean CT number in a region of interest
- The difference between maximum and minimum CT numbers in the image
- The number of image artifacts present
- The standard deviation of CT numbers in a uniform region of interest (Correct answer)
Correct answer: The standard deviation of CT numbers in a uniform region of interest
Image noise in CT is quantified as the standard deviation of HU values within a uniform phantom region; higher standard deviation indicates greater noise.
Question 142: Which radiation weighting factor (wR) applies to X-rays used in CT imaging?
- 1 (Correct answer)
- 20
- 2
- 5
Correct answer: 1
X-rays and gamma rays have a radiation weighting factor of 1, meaning 1 Gy equals 1 Sv.
Question 143: A candidate applies for CT certification under the structured education pathway. Which type of program must they have completed?
- Any radiology-related online course
- A self-designed independent study program
- A hospital orientation program
- A CT-specific structured education program accredited by a recognized body (Correct answer)
Correct answer: A CT-specific structured education program accredited by a recognized body
The structured education pathway requires completion of a CT program accredited by a body recognized by ARRT, such as JRCERT.
Question 144: How many continuing education (CE) credits are required for recertification in ARRT CT?
- 12 CE credits
- 40 CE credits
- 24 CE credits (Correct answer)
- 20 CE credits
Correct answer: 24 CE credits
To maintain ARRT CT certification, technologists must complete a specific number of continuing education (CE) credits within each two-year renewal period. The requirement is 24 CE credits, which helps ensure that certified professionals stay updated with advancements and best practices in the field of computed tomography.
Question 145: Which of the following is a potential benefit of obtaining ARRT CT certification?
- Increased job security and advancement opportunities (Correct answer)
- Exemption from state licensure requirements
- A significant reduction in the required continuing education hours
- Eligibility for an automatic salary increase
Correct answer: Increased job security and advancement opportunities
Obtaining ARRT CT certification demonstrates a specialized skill set and commitment to professional standards, which is highly valued by employers. This often translates into increased job security, as certified professionals are preferred, and opens doors to advancement opportunities within the medical imaging field.
Question 146: A CT technologist notices the dose reference level (DRL) for a routine chest CT is being routinely exceeded. The BEST first step is to:
- Continue scanning since DRLs are not legally binding limits
- Report the finding only to the radiologist and take no further action
- Immediately halve the mAs for all chest CT exams
- Review and optimize the scan protocol to determine if dose can be reduced without compromising diagnostic quality (Correct answer)
Correct answer: Review and optimize the scan protocol to determine if dose can be reduced without compromising diagnostic quality
DRLs serve as benchmarks; exceeding them triggers a protocol review to identify optimization opportunities while preserving diagnostic image quality.
Question 147: Which artifact appears as a dark band between two high-density objects on a CT image and is caused by beam hardening?
- Moiré artifact
- Windmill artifact
- Shadowing or 'dark band' artifact (Correct answer)
- Ring artifact
Correct answer: Shadowing or 'dark band' artifact
Dark bands (also called 'shadowing' or 'cupping' between dense objects) arise from extreme beam hardening where few low-energy photons survive to reach the detector between two dense structures.
Question 148: Which of the following is NOT a requirement for ARRT CT post-primary certification eligibility?
- Completing required structured education in CT
- Meeting clinical experience requirements in CT procedures
- Holding a current, unrestricted ARRT credential in a qualifying discipline
- Graduating from a JRCERT-accredited CT-specific degree program (Correct answer)
Correct answer: Graduating from a JRCERT-accredited CT-specific degree program
CT certification does not require graduation from a JRCERT-accredited CT degree program; structured education and clinical experience through other approved pathways are accepted.
Question 149: On axial CT of the knee, the iliotibial band is best identified at which location?
- Posterior to the lateral collateral ligament at the fibular head
- Posterolateral aspect of the knee, inserting on the femoral condyle
- Lateral aspect of the knee, inserting on Gerdy's tubercle of the tibia (Correct answer)
- Anteromedial compartment between the patellar tendon and medial collateral ligament
Correct answer: Lateral aspect of the knee, inserting on Gerdy's tubercle of the tibia
The iliotibial band runs along the lateral thigh and inserts on Gerdy's tubercle on the anterolateral tibia.
Question 150: In CT dose reporting, CTDI_vol represents:
- Dose only at the center of the phantom
- Volume-averaged radiation dose within the scan volume (Correct answer)
- Dose at a single point in the patient
- Total energy deposited in the room
Correct answer: Volume-averaged radiation dose within the scan volume
CTDI_vol is the volume CT dose index, representing average dose within the irradiated volume; it accounts for pitch in helical scanning.
Question 151: In CT, the term 'isotropic voxel' means:
- The voxel's HU value is calibrated to water
- The voxel represents a single tissue type
- The voxel has no noise contribution
- The voxel dimensions are equal in all three axes (x, y, z) (Correct answer)
Correct answer: The voxel dimensions are equal in all three axes (x, y, z)
An isotropic voxel has equal dimensions in x, y, and z directions, enabling multiplanar reformats of equal quality in any plane.
Question 152: How long is the ARRT CT post-primary certification credential valid before renewal is required?
- 5 years
- 2 years (biennium) (Correct answer)
- Lifetime with no renewal
- 1 year
Correct answer: 2 years (biennium)
Like all ARRT credentials, CT post-primary certification must be renewed every two years through the biennial renewal process.
Question 153: Cardiac motion artifacts on coronary CT angiography are primarily reduced by which technique?
- ECG gating to synchronize data acquisition with the cardiac cycle (Correct answer)
- Administering iodinated contrast slowly
- High-pitch helical scanning only
- Using maximum mAs
Correct answer: ECG gating to synchronize data acquisition with the cardiac cycle
ECG gating synchronizes CT data acquisition to the relatively motion-free phases of the cardiac cycle (typically mid-diastole), reducing coronary motion artifact.
Question 154: A CT technologist who allows their ARRT registration to lapse must do which of the following to reinstate it?
- Retake the primary certification exam
- Apply through JRCERT for re-entry
- Complete a reinstatement application and pay the reinstatement fee (Correct answer)
- Repeat clinical training
Correct answer: Complete a reinstatement application and pay the reinstatement fee
Lapsed registrants must submit a reinstatement application with the appropriate fee and may need to fulfill CE requirements.
Question 155: In CT quality control, 'low-contrast detectability' refers to the system's ability to:
- Distinguish objects with small differences in attenuation from background (Correct answer)
- Resolve fine structural detail in bone
- Determine the maximum scan field of view
- Measure exact CT numbers for each tissue type
Correct answer: Distinguish objects with small differences in attenuation from background
Low-contrast detectability measures the scanner's ability to visualize objects with subtle attenuation differences, which is critical for soft-tissue diagnosis.
Question 156: A CT head without contrast shows a hyperdense crescent-shaped collection along the inner table of the skull. This is most consistent with:
- Subarachnoid hemorrhage
- Acute subdural hematoma (Correct answer)
- Epidural hematoma
- Intraparenchymal hematoma
Correct answer: Acute subdural hematoma
Acute subdural hematomas appear as hyperdense crescent-shaped collections that conform to the brain surface and cross suture lines.
Question 157: Which artifact appears as bright or dark bands radiating from high-density structures like metal implants?
- Streak artifact (Correct answer)
- Beam hardening artifact
- Partial volume artifact
- Ring artifact
Correct answer: Streak artifact
Streak artifacts arise from highly attenuating objects (metal, dense bone) causing inconsistent projections that reconstruct as linear streaks.
Question 158: During a CT angiography of the neck (CTA neck), the scan direction is typically:
- Caudal to cranial (Correct answer)
- Bidirectional simultaneously
- Cranial to caudal
- Axial only without table movement
Correct answer: Caudal to cranial
CTA of the neck scans caudal to cranial to follow the contrast bolus as it travels superiorly through the carotid and vertebral arteries.
Question 159: Which artifact is caused by patient movement during CT data acquisition and appears as blurring or ghosting on the reconstructed image?
- Cupping artifact
- Motion artifact (Correct answer)
- Partial volume artifact
- Aliasing artifact
Correct answer: Motion artifact
Motion artifacts result from patient movement during scanning, causing inconsistent data at each projection angle and manifesting as blurring or streaking.
Question 160: Under ARRT's Continuing Qualifications Requirements (CQR), what must credential holders demonstrate?
- Completion of a new clinical rotation every 10 years
- A passing score on a repeat certification exam every 10 years
- Employer attestation of satisfactory job performance
- Ongoing competency through self-assessment and structured activities related to their discipline (Correct answer)
Correct answer: Ongoing competency through self-assessment and structured activities related to their discipline
CQR requires credential holders to complete self-assessment and structured CE activities demonstrating continued competency in their specialty.
Question 161: An ARRT-certified CT technologist moves to a state that also requires state licensure for CT practice. Which statement is true?
- ARRT certification replaces all state licensing requirements
- State licensure and ARRT certification are separate and both may be required (Correct answer)
- State licensure CE requirements always mirror ARRT requirements exactly
- ARRT automatically notifies the state upon renewal
Correct answer: State licensure and ARRT certification are separate and both may be required
ARRT certification and state licensure are independent processes; meeting ARRT standards does not automatically satisfy state licensing requirements.
Question 162: How does ARRT CT certification influence a technologist's ability to work at facilities affiliated with academic medical centers?
- Academic medical centers often require specialty certifications for positions involving advanced imaging modalities (Correct answer)
- It only matters for technologists who also teach radiology students
- It is disqualifying because academic centers prefer non-certified staff
- It is irrelevant because academic centers set their own competency standards independently of ARRT
Correct answer: Academic medical centers often require specialty certifications for positions involving advanced imaging modalities
Academic medical centers frequently list specialty ARRT certifications as required or preferred qualifications for CT positions due to their high-acuity patient populations.
Question 163: Partial volume averaging artifact in CT is BEST minimized by:
- Using a smoother reconstruction kernel
- Decreasing the tube current
- Increasing the reconstruction matrix
- Using thinner slice collimation (Correct answer)
Correct answer: Using thinner slice collimation
Thinner slices reduce the z-axis extent of each voxel, decreasing the chance that multiple tissue types are averaged into a single voxel.
Question 164: A radiologic technologist notices that CT images of the liver appear uniformly noisy despite using standard mAs. The MOST appropriate first corrective action is:
- Double the mAs for the repeat scan immediately
- Verify that the correct reconstruction kernel and algorithm are applied (Correct answer)
- Switch to a narrower window width for display
- Reduce the reconstruction FOV by 50%
Correct answer: Verify that the correct reconstruction kernel and algorithm are applied
Verifying protocol settings (kernel, algorithm, slice thickness) first ensures the source of apparent noise is identified before unnecessarily increasing dose.
Question 165: Which reconstruction kernel (filter) choice produces the HIGHEST spatial resolution but MOST noise in CT?
- Soft/smooth kernel
- Sharp/edge-enhancing kernel (Correct answer)
- Lung kernel
- Standard kernel
Correct answer: Sharp/edge-enhancing kernel
Sharp or bone kernels enhance high-frequency data to improve edge detail but amplify noise, making them high-resolution but noisy.
Question 166: What are the four basic tissue types in the human body?
- Skin, bone, blood, and fat
- Smooth, rough, dense, and loose
- Epithelial, connective, muscle, and nervous (Correct answer)
- Brain, heart, lung, and liver
Correct answer: Epithelial, connective, muscle, and nervous
The four fundamental tissue types are epithelial (covering/lining), connective (support/connection), muscle (movement), and nervous (communication/control).
Question 167: In a CT perfusion study of the brain, which parameter measures the volume of blood in a given unit of brain tissue?
- Cerebral blood volume (CBV) (Correct answer)
- Mean transit time (MTT)
- Cerebral blood flow (CBF)
- Time to peak (TTP)
Correct answer: Cerebral blood volume (CBV)
Cerebral blood volume (CBV) represents the total volume of blood within a defined brain tissue volume, measured in mL/100g.
Question 168: The window level (WL) in CT display refers to:
- The center Hounsfield unit value of the displayed grayscale range (Correct answer)
- The reconstruction matrix size
- The total range of Hounsfield units shown
- The minimum threshold for bone segmentation
Correct answer: The center Hounsfield unit value of the displayed grayscale range
Window level sets the midpoint of the HU range being displayed, determining which tissue densities appear as medium gray on the monitor.
Question 169: Which statement about the ARRT CT examination content specifications is accurate?
- They are developed and periodically updated by ARRT based on practice analysis surveys (Correct answer)
- They are set by individual state radiation control programs
- They mirror the ACR practice parameters exactly
- They have not changed since 2000
Correct answer: They are developed and periodically updated by ARRT based on practice analysis surveys
ARRT periodically conducts practice analysis surveys of working technologists to keep examination content relevant to current clinical practice.
Question 170: What is the primary purpose of ARRT's structured competency-based renewal requirements for CT certification?
- To align with Medicare billing requirements
- To limit the number of active CT technologists
- To ensure technologists maintain current knowledge and skills (Correct answer)
- To increase revenue for the ARRT organization
Correct answer: To ensure technologists maintain current knowledge and skills
ARRT's renewal structure is designed to ensure that certified professionals stay current with evolving technology, safety standards, and clinical practice.
Question 171: Aliasing artifacts in CT, which appear as fine streaks or Moiré patterns, are caused by which factor?
- Insufficient detector sampling (Correct answer)
- Excessive patient size
- Incorrect table speed
- High kVp settings
Correct answer: Insufficient detector sampling
Aliasing artifacts occur when the object being imaged contains spatial frequencies higher than the detector sampling rate can capture, per the Nyquist theorem.
Question 172: Which of the following patient populations has the HIGHEST radiosensitivity?
- Elderly patients over 75
- Pregnant women in the third trimester
- Adult males aged 40-60
- Fetuses and children under 5 years of age (Correct answer)
Correct answer: Fetuses and children under 5 years of age
Fetuses and young children are most radiosensitive due to rapidly dividing cells and longer life expectancy over which stochastic effects can manifest.
Question 173: Which approach is used in a split-bolus IV contrast protocol for CT of the abdomen?
- A single rapid bolus followed by immediate scanning
- Saline flush only with no contrast
- Two separate injections given at different time points before scanning (Correct answer)
- Contrast injected into the portal vein directly
Correct answer: Two separate injections given at different time points before scanning
The split-bolus technique delivers two injections at different time intervals so a single scan pass captures both nephrographic and excretory phases simultaneously.
Question 174: CT window width (WW) setting controls which aspect of image display?
- The overall brightness of the image
- The spatial resolution of the image
- The range of Hounsfield units displayed as the full gray scale from black to white (Correct answer)
- The center Hounsfield unit of the gray scale
Correct answer: The range of Hounsfield units displayed as the full gray scale from black to white
Window width determines the range of CT numbers (HU) mapped to the grayscale; a narrow window increases contrast but limits the HU range displayed.
Question 175: A technologist reconstructs axial CT images with 5 mm thickness then reforms sagittal images showing 'staircase' appearance. The BEST solution is:
- Use a sharper reconstruction kernel
- Increase mAs for the next scan
- Increase the reconstruction FOV
- Reconstruct using thinner overlapping slices before reformatting (Correct answer)
Correct answer: Reconstruct using thinner overlapping slices before reformatting
Staircase artifact on reformats results from thick axial slices; reconstructing thinner overlapping slices provides finer z-axis sampling and smoother multiplanar reformats.
Question 176: What is the correct technique for removing contaminated gloves to prevent self-contamination?
- Snap gloves off at the wrist and discard immediately
- Wash gloves with soap and water before removal
- Pull both gloves off by the fingertips simultaneously
- Peel one glove inside-out from the wrist, then use bare fingers inside the second glove's wrist to remove it (Correct answer)
Correct answer: Peel one glove inside-out from the wrist, then use bare fingers inside the second glove's wrist to remove it
The proper technique keeps contaminated outer surfaces folded inside during removal so bare skin never contacts the contaminated exterior.
Question 177: What is the recommended frequency for performing a full CT equipment performance evaluation by a qualified medical physicist?
- Every five years
- Daily
- Annually (Correct answer)
- Weekly
Correct answer: Annually
ACR and AAPM guidelines recommend a comprehensive CT performance evaluation by a qualified medical physicist at least annually.
Question 178: What is the function of epithelial tissue?
- To store fat
- To contract and produce movement
- To transmit electrical signals
- To cover body surfaces, line cavities, and form glands (Correct answer)
Correct answer: To cover body surfaces, line cavities, and form glands
Epithelial tissue covers all body surfaces, lines body cavities and organs, and forms glands. It provides protection, absorption, secretion, and sensation.
Question 179: Iterative reconstruction (IR) techniques in CT offer which primary advantage over filtered back projection?
- Reduced image noise at the same or lower radiation dose (Correct answer)
- Higher spatial resolution
- Faster reconstruction speed
- Elimination of all artifacts
Correct answer: Reduced image noise at the same or lower radiation dose
IR algorithms use repeated mathematical modeling of the imaging process to suppress noise, allowing diagnostic image quality to be maintained at reduced mAs and dose.
Question 180: What is the primary purpose of the CT dose index (CTDI)?
- To calculate the effective dose to the technologist
- To determine scatter radiation levels in the control room
- To characterize radiation output of a CT scanner independent of patient size (Correct answer)
- To measure patient absorbed dose in a single organ
Correct answer: To characterize radiation output of a CT scanner independent of patient size
CTDI characterizes the radiation output of a CT scanner and allows standardized comparison between scanners and protocols.
Question 181: Increasing the reconstruction field of view (FOV) while keeping matrix size constant will:
- Increase pixel size and decrease spatial resolution (Correct answer)
- Have no effect on spatial resolution
- Increase noise while improving contrast
- Decrease pixel size and increase spatial resolution
Correct answer: Increase pixel size and decrease spatial resolution
Larger FOV with the same matrix means each pixel covers more area, increasing pixel size and reducing spatial resolution.
Question 182: An automatic exposure control (AEC) system in CT adjusts which parameter in real time?
- Detector row width
- Tube current (mA) based on patient attenuation (Correct answer)
- Gantry rotation speed
- Reconstruction kernel
Correct answer: Tube current (mA) based on patient attenuation
CT AEC (tube current modulation) automatically adjusts mA based on patient size and attenuation to maintain consistent image quality at optimal dose.
Question 183: What does CT stand for in medical imaging?
- Central Treatment
- Computed Tomography (Correct answer)
- Cardiac Testing
- Clinical Therapy
Correct answer: Computed Tomography
CT (Computed Tomography) uses X-ray technology and computer processing to create detailed cross-sectional images of the body.
Question 184: A patient with a cardiac pacemaker presents for chest CT. Which artifact should the technologist anticipate?
- Ring artifact
- Metallic streak artifact from the pacemaker leads and generator (Correct answer)
- Cupping artifact
- Windmill artifact
Correct answer: Metallic streak artifact from the pacemaker leads and generator
Pacemaker generators and leads are highly attenuating metallic objects that produce characteristic beam hardening streak artifacts on chest CT.
Question 185: What is the purpose of a risk assessment?
- To track inventory levels
- To calculate financial budgets
- To identify potential hazards and determine mitigation measures (Correct answer)
- To assign work shifts
Correct answer: To identify potential hazards and determine mitigation measures
Risk assessments identify potential hazards, evaluate the likelihood and severity of harm, and determine appropriate controls to minimize risk.
Question 186: What is the application window for the ARRT CT post-primary examination after a candidate is deemed eligible?
- 30 days from approval to test
- Six months from approval to test
- One year from approval to test (Correct answer)
- Two years from approval to test
Correct answer: One year from approval to test
Once approved, ARRT candidates have one year to schedule and sit for the post-primary CT examination.
Question 187: A CT scan for appendicitis in a young female patient of childbearing age should be preceded by:
- Administration of glucagon
- Double dose of IV contrast
- Evaluation for pregnancy and consideration of alternative imaging (Correct answer)
- Lung window reconstruction
Correct answer: Evaluation for pregnancy and consideration of alternative imaging
Radiation dose to a fetus is a critical concern; pregnancy should be assessed and ultrasound or MRI considered as alternatives before CT in reproductive-age females.
Question 188: Which of these statements is true about eligibility for ARRT CT certification?
- Clinical competencies must be completed after passing the CT exam.
- Applicants must hold an existing ARRT certification in an eligible primary pathway discipline. (Correct answer)
- Holding a state radiography license is enough to apply for certification.
- Only professionals with a master's degree can apply for CT certification.
Correct answer: Applicants must hold an existing ARRT certification in an eligible primary pathway discipline.
ARRT CT certification is considered a post-primary certification, meaning it builds upon a foundational credential. Therefore, a prerequisite for applying is holding an active ARRT certification in a primary pathway discipline such as radiography, nuclear medicine technology, or radiation therapy. This ensures applicants have a core understanding of medical imaging principles.
Question 189: In CT, the modulation transfer function (MTF) is used to characterize:
- Contrast resolution at different tissue densities
- Detector quantum efficiency
- Patient dose efficiency
- Spatial frequency response and limiting spatial resolution (Correct answer)
Correct answer: Spatial frequency response and limiting spatial resolution
The MTF describes how well the CT system transfers spatial frequencies from object to image, defining the system's spatial resolution capability.
Question 190: Which of the following is a valid reason ARRT may revoke or suspend a technologist's CT certification?
- Transferring employment to a different imaging facility
- Completing CE credits after the renewal deadline
- Failure to update a home address in the ARRT database
- Violation of the ARRT Standards of Ethics (Correct answer)
Correct answer: Violation of the ARRT Standards of Ethics
ARRT can revoke or suspend certification for violations of its Standards of Ethics, which govern professional and personal conduct.
Question 191: Which post-processing technique is most appropriate for evaluating luminal stenosis of the carotid arteries on a CT angiogram?
- Minimum intensity projection (MinIP)
- Standard axial images only
- Multiplanar reformation combined with MIP (Correct answer)
- Volume rendering alone
Correct answer: Multiplanar reformation combined with MIP
Combining MPR (which shows vessel walls and plaques in cross-section) with MIP (which shows the lumen in projection) gives the most complete assessment of carotid stenosis.
Question 192: Which CT parameter most directly controls the amount of radiation dose delivered to the patient?
- Reconstruction kernel
- Pitch
- mAs (Correct answer)
- kVp
Correct answer: mAs
mAs (milliampere-seconds) directly determines the number of X-ray photons produced and is the primary controller of patient dose.
Question 193: Which reconstruction field of view (FOV) is most appropriate when performing targeted high-resolution CT of the temporal bone?
- 25 cm (medium FOV)
- 10–15 cm (small targeted FOV) (Correct answer)
- 40 cm (large FOV)
- 50 cm (full body FOV)
Correct answer: 10–15 cm (small targeted FOV)
A 10–15 cm reconstruction FOV over the temporal bone maximizes pixel density within the small region of interest, yielding the highest possible spatial resolution.
Question 194: Which type of iodinated contrast media is considered safest for patients at risk for contrast-induced nephropathy?
- Low-osmolar ionic contrast
- High-osmolar ionic contrast
- Iso-osmolar nonionic contrast (Correct answer)
- High-osmolar nonionic contrast
Correct answer: Iso-osmolar nonionic contrast
Iso-osmolar nonionic contrast (e.g., iodixanol) has the lowest nephrotoxic potential and is preferred for high-risk patients.
ARRT Computed Tomography (CT) Certification Examination
The ARRT CT certification exam assesses entry-level knowledge and cognitive skills required for computed tomography practice, covering patient care, radiation safety, image production, and CT imaging procedures across all major anatomical regions.
Exam Rules
- You can skip questions and return to them later
- Flag questions for review before submitting
- No feedback shown until you submit the entire exam
- Unanswered questions count as wrong — answer everything
- 10 pretest questions are mixed in and don't affect your score
- Timer auto-submits when time runs out
- Your progress is auto-saved every 30 seconds