Pressure Testing Flashcards

7 cards from real API 510 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Pressure Testing flashcards as text
  1. When performing a sensitivity leak test using pneumatic pressure, what method is commonly used to detect leaks?

    Answer: Soap bubble solution or equivalent

    Soap bubble solution applied to joints and welds is the standard method for detecting leaks during pneumatic pressure testing.

  2. What is the typical pressure hold time required for a hydrostatic leak test per ASME Code?

    Answer: 10 minutes

    ASME Code typically requires a minimum 30-minute hold at test pressure for hydrostatic tests before inspecting the vessel.

  3. A vessel with a corrosion allowance nearly consumed is scheduled for a pressure test. What special concern applies?

    Answer: Evaluate remaining wall thickness to ensure it can withstand test pressure without risk of failure

    The remaining wall thickness must be verified to confirm the vessel can safely sustain the test pressure without risk of failure or plastic deformation.

  4. Which of the following best describes an 'alteration' to a pressure vessel per API 510?

    Answer: A physical change that affects the pressure-containing capability beyond original design

    An alteration is any physical change that affects the pressure-containing capability of the vessel beyond the original design.

  5. For a pressure vessel in cryogenic service, what special consideration applies when selecting a pressure test medium?

    Answer: Water or gas at ambient temperature may be used with appropriate precautions

    Water or inert gas at ambient temperature is generally used for cryogenic vessel testing since the actual cryogenic fluid is not needed for the pressure test itself.

  6. What action should be taken when a pressure gauge used during testing reads erratically or is suspected to be inaccurate?

    Answer: Replace or calibrate the gauge before proceeding with the test

    An inaccurate gauge must be replaced or calibrated before testing continues to ensure the correct test pressure is applied.

  7. How many pressure gauges are typically recommended during a pressure test to ensure accuracy?

    Answer: Two gauges — one at the pressure source and one on the vessel

    Using two gauges — one at the pressurization source and one on the vessel itself — provides verification of test pressure and detects any discrepancy.