When using a hydraulic crimping tool on high-voltage cable lugs, what must be verified before each crimp cycle?
Answer: Hydraulic fluid level and die alignment
Correct hydraulic fluid level ensures full tonnage is achieved, and die alignment prevents off-center crimps that weaken the connection.
An AEP lineman needs to cut a live secondary conductor using approved insulated tools. Which tool is specifically designed for this task?
Answer: Insulated bolt cutter
Insulated bolt cutters rated for the applicable voltage are the correct tool for cutting energized secondary conductors safely.
A hot stick's insulating section must be kept free of contaminants. Which cleaning agent is approved for fiberglass hot sticks?
Answer: Isopropyl alcohol or approved dielectric cleaner
Isopropyl alcohol or manufacturer-approved dielectric cleaners remove surface contamination without degrading the fiberglass matrix.
What is the primary function of a load buster tool when used on a distribution system?
Answer: Safely interrupting energized cutout fuses under load
A load buster (or load break tool) absorbs the arc energy when opening an energized cutout, preventing damage and injury.
During transformer installation, a come-along (lever hoist) begins to slip under load. The correct immediate action is to:
Answer: Lower the load, inspect the ratchet mechanism, and replace if worn
A slipping ratchet indicates wear or damage; continuing to lift risks uncontrolled load release, so the tool must be inspected and replaced.
When setting up a portable generator at an AEP storm restoration site, which grounding step is required before energizing loads?
Answer: Connect the frame to a driven ground rod
The generator frame must be bonded to an earth ground rod to provide a safe fault current path and prevent touch voltage hazards.
A dielectric glove that passes an air inflation test but shows a small pinhole when immersed in water should be:
Answer: Removed from service and destroyed
Any puncture or pinhole compromises the glove's insulating integrity; it must be removed from service and destroyed to prevent accidental reuse.