  1. A technician measures suction pressure significantly above normal and discharge pressure below normal on a residential split system. What is the most likely cause?

    Answer: Compressor valve failure

    Compressor valve failure causes high suction and low discharge pressure because refrigerant bypasses the compressor valves instead of being properly compressed.

  2. During a service call, a homeowner reports the system runs continuously but never reaches setpoint. The evaporator coil is partially frosted. What should the technician check first?

    Answer: Airflow across the evaporator coil

    Restricted airflow is the most common cause of evaporator coil frosting and inadequate cooling, and should be checked before electrical components.

  3. A technician finds the high-pressure switch tripping repeatedly on a hot day. Condenser coil appears clean. What is the next most likely cause?

    Answer: Condenser fan motor failure or reduced airflow

    A faulty or undersized condenser fan results in inadequate heat rejection, causing head pressure to rise and trip the high-pressure switch.

  4. What does a high superheat AND high subcooling reading together most likely indicate?

    Answer: Restriction in the liquid line or metering device

    High subcooling indicates liquid refrigerant is backing up before a restriction, while high superheat indicates insufficient refrigerant reaching the evaporator.

  5. A technician suspects a refrigerant leak. After recovering and recharging, what is the correct procedure before returning the system to service?

    Answer: Pressurize with nitrogen and perform a leak test

    After any repair, the system must be pressure-tested with nitrogen to confirm the repair is leak-free before evacuation and recharge.

  6. A residential system has correct refrigerant charge but the supply air temperature differential (delta-T) is only 10°F instead of the expected 16–22°F. What is the most likely cause?

    Answer: Excessive airflow across the evaporator

    Too much airflow across the evaporator reduces the time the air has to exchange heat, resulting in a lower temperature differential.

  7. When using an electronic leak detector and no leak is found at suspected areas, what technique should the technician use next?

    Answer: Use UV dye and a UV light to locate the leak

    UV dye inspection is an effective secondary method to locate leaks that electronic detectors may miss, especially slow or intermittent leaks.