System Installation and Brazing Flashcards

7 cards from real 313D practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 System Installation and Brazing flashcards as text
  1. When brazing copper refrigerant lines, what minimum silver content is required for the brazing alloy used in most residential AC applications?

    Answer: 15% silver

    Brazing alloys with at least 15% silver content are typically required for refrigerant line brazing to ensure strong, leak-free joints.

  2. Nitrogen should be flowing through refrigerant lines during brazing primarily to:

    Answer: Prevent internal oxidation and scale formation

    Flowing dry nitrogen through the tubing during brazing displaces oxygen and prevents the formation of copper oxide scale inside the lines.

  3. What is the correct sequence for making a brazed refrigerant line connection?

    Answer: Insert tube, apply flux, heat joint to brazing temp, apply filler

    The proper sequence is to insert the tube fully, apply flux if needed, heat the joint evenly to brazing temperature, then apply the filler rod at the joint.

  4. When installing a split-system air conditioner, the indoor unit's condensate drain line should be pitched at a minimum slope of:

    Answer: 1/4 inch per foot

    A minimum slope of 1/4 inch per foot ensures proper gravity drainage of condensate without pooling.

  5. Which tool is used to properly size copper tubing for flare or swage connections during installation?

    Answer: Tubing cutter and deburring tool

    A tubing cutter makes a clean, square cut and the deburring tool removes the inner burr to ensure a leak-free connection.

  6. During a residential AC installation, the outdoor condenser unit should be elevated above grade to:

    Answer: Prevent flooding and allow air circulation beneath the unit

    Elevating the condenser on a pad protects it from standing water and allows proper airflow under the unit.

  7. What is the purpose of adding a trap in the suction line when the evaporator coil is located above the condensing unit?

    Answer: To prevent oil from draining back to the compressor during the off cycle

    A suction line trap prevents oil from draining back into the compressor crankcase when the system is off, which could cause liquid slugging on startup.