- Which Manual D concept defines the path through the duct system with the greatest pressure drop? → Critical path
- What is the purpose of applying a 'safety factor' or equipment oversizing limit in residential load calculations? → To prevent excessive short cycling while ensuring comfort
- What does a micron gauge measure during the evacuation of an air conditioning system? → Absolute pressure in the system
- When routing refrigerant lines through a wall or floor, the technician should: → Install a protective sleeve or grommet to prevent abrasion
- Which document must a refrigerant reclaimation facility provide to verify that recovered refrigerant meets AHRI 700 purity standards? → Certificate of Reclaim (analysis report)
- Which of the following is a safety control designed to shut down the compressor if the refrigerant pressure on the high side becomes dangerously high? → High-pressure switch
- Which NEC article primarily governs the installation of air-conditioning and refrigerating equipment? → Article 440
- Under the NEC, which article specifically addresses wiring methods and equipment for air conditioning and refrigerating equipment? → Article 440
- What is the purpose of the crankcase heater on a compressor? → To prevent refrigerant migration and oil dilution in the crankcase during off cycles
- During a nitrogen pressure test on a refrigerant system, the technician should use a: → Dry nitrogen cylinder with a pressure regulator set to the test pressure
- What is the minimum slope required for a condensate drain line in a residential installation to ensure gravity drainage? → 1/4 inch per foot
- A residential system is charged by weight per manufacturer specifications, but superheat is still too high after charging. What should the technician do next? → Check for airflow restrictions, TXV operation, or refrigerant distribution issues
- What is the correct method for charging a new R-410A system that was evacuated and requires a full charge per manufacturer nameplate? → Charge liquid refrigerant through the high-side service port with the system off
- When a schematic shows a relay coil labeled 'IFR' (Indoor Fan Relay) with its associated contacts shown elsewhere in the diagram, the contacts will be labeled: → IFR with a number suffix to indicate which contact set they belong to
- In troubleshooting with a schematic, if voltage is present on both sides of a normally closed safety switch, what does this indicate? → The switch has opened (tripped) and is blocking current flow to the load
- What is the primary purpose of adding superheat to the refrigerant vapor before it leaves the evaporator? → To ensure only vapor enters the compressor, preventing damage.
- What indoor relative humidity range does ASHRAE recommend for occupant comfort in residential buildings? → 30–60%
- A new installation has the outdoor unit located 60 feet below the indoor unit. What additional installation step is required for the refrigerant piping? → Install oil traps in the suction line riser every 20 feet
- Which refrigerant cylinder color code is used to identify R-410A? → Rose/pink
- What is the function of a filter-drier in a refrigerant circuit? → Remove moisture and contaminants from the refrigerant
- What does a high-pressure switch do in the electrical circuit of a residential air conditioner? → Opens the control circuit if refrigerant pressure exceeds a safe limit
- Why is it critical to keep moisture out of recovered R-410A refrigerant? → Moisture reacts with POE oil to form acids that damage compressors
- What is subcooling in a refrigeration system? → Chilling the refrigerant liquid below its condensing saturation temperature
- A homeowner reports that their new AC system is making a gurgling noise from the indoor coil. What is the MOST likely cause? → Air or non-condensables in the refrigerant circuit
- Under the 2021 International Residential Code, what is the minimum required capacity for a condensate overflow shutoff device? → The device must stop the unit before the overflow pan fills
- Which terminal on a residential heat pump thermostat controls the reversing valve for switching between heating and cooling modes? → O or B
- In rectangular duct design, what does the term 'aspect ratio' describe? → The ratio of the duct's longer side to its shorter side.
- Which section of the International Mechanical Code specifies the required access opening dimensions for HVAC equipment installed in attic spaces? → IMC Section 306
- A technician finds the outdoor unit operating but no air movement from supply registers. The indoor unit is energized. What is the most logical first check? → Indoor blower motor and capacitor
- A technician is installing a new condensing unit on an unlevel gravel bed. What is the proper first step to ensure long-term reliability of the unit? → Pour a new, level concrete pad or install a high-impact plastic pad.